{"created":"2023-05-15T14:44:13.535854+00:00","id":60471,"links":{},"metadata":{"_buckets":{"deposit":"96a41c32-e30b-42b3-81b7-6b2e5b2a8240"},"_deposit":{"created_by":1,"id":"60471","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"60471"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00060471","sets":["10:29"]},"author_link":["600408","600409"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2004-06-23","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A high-performance brain PET scanner, jPET-D4, is under development. This scanner is designed to achieve not only high spatial resolution but also high scanner sensitivity with depth-of-interaction (DOI) measurement using four-layered thin crystals. A pair of detector blocks and a coincidence circuit have been assembled into an experimental prototype. As a preliminary experiment, we have investigated the performance of jPET-D4 in inherent spatial resolution. In conclusions, first experimental measurements promise an excellent resolution performance of jPET-D4.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"Society of Nuclear Medicine's 51st Annual Meeting","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yamaya, Taiga"}],"nameIdentifiers":[{"nameIdentifier":"600408","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山谷 泰賀","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"600409","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"A First Performance Evaluation of A Novel Brain DOI-PET Scanner - jPET-D4","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"A First Performance Evaluation of A Novel Brain DOI-PET Scanner - jPET-D4"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2004-07-01"},"publish_date":"2004-07-01","publish_status":"0","recid":"60471","relation_version_is_last":true,"title":["A First Performance Evaluation of A Novel Brain DOI-PET Scanner - jPET-D4"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:53:24.055037+00:00"}