{"created":"2023-05-15T14:44:07.822171+00:00","id":60343,"links":{},"metadata":{"_buckets":{"deposit":"ab938b5f-31d0-4e92-8697-6e37f40f32c4"},"_deposit":{"created_by":1,"id":"60343","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"60343"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00060343","sets":["10:29"]},"author_link":["599397","599398"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2003-08-07","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The proposed detector, which units a NaI(Tl) scintillator, a same-shaped BGO scintillator with a photomultiplier tube, positively increases directional sensitivity to incident gamma rays and has a possibility of measuring directions of gamma rays, and searching radioactive materials. Prototypes have been designed and examined by laboratory tests. It is shown that the detector with scintillators of 25mm in diameter by 50mm in length has the sufficient sensitivity to meet the requirement.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"SICE 2003","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Shirakawa, Yoshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"599397","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白川 芳幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"599398","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Responses of directional Gamma Ray Scintillation Detctors for Searching radioactive materials","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Responses of directional Gamma Ray Scintillation Detctors for Searching radioactive materials"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2004-04-19"},"publish_date":"2004-04-19","publish_status":"0","recid":"60343","relation_version_is_last":true,"title":["Responses of directional Gamma Ray Scintillation Detctors for Searching radioactive materials"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:54:48.390152+00:00"}