{"created":"2023-05-15T14:43:57.958599+00:00","id":60126,"links":{},"metadata":{"_buckets":{"deposit":"5f827b7c-ec6d-4ddb-8242-2347a8938c35"},"_deposit":{"created_by":1,"id":"60126","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"60126"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00060126","sets":["10:29"]},"author_link":["597836","597835"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2003-11-13","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The HIMAC synchrotron has employed two slow-extraction schemes: the RF-KO extraction and the ordinary resonant extraction method. The former has been utilized mainly for the cancer therapy, while the later for counter experiments in the physics research. In both extraction schemes, the horizontal RF field with mono frequency, corresponding to the tune around stop-band, can suppress the spill ripple sufficiently. The paper describes the experimental result on this method.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第14回加速器科学研究発表会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Noda, Kouji"}],"nameIdentifiers":[{"nameIdentifier":"597835","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 耕司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"597836","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Slow beam extraction at the HIMAC synchrotron","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Slow beam extraction at the HIMAC synchrotron"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-11-13"},"publish_date":"2003-11-13","publish_status":"0","recid":"60126","relation_version_is_last":true,"title":["Slow beam extraction at the HIMAC synchrotron"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:57:13.123455+00:00"}