{"created":"2023-05-15T14:43:53.845554+00:00","id":60050,"links":{},"metadata":{"_buckets":{"deposit":"7136adf5-e102-4531-9a80-8d494560cc7f"},"_deposit":{"created_by":1,"id":"60050","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"60050"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00060050","sets":["10:29"]},"author_link":["597148","597143","597147","597150","597151","597145","597152","597137","597140","597141","597142","597136","597149","597144","597135","597154","597156","597139","597155","597146","597153","597138"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2003-10-29","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"PET-CTではX線CTデータを用いて吸収補正を行う。通常PETの外部線源を用いたtransmission \ndataと比べてX線CTデータは空間分解能が高く、ノイズが少なく、吸収補正されたPETの画質に有利であると考えられる。以上の観点から、われわれはPET-CT画像と従来の外部線源(68Ge線源)による吸収補正PET画像との画質の比較と、ROI値の比較を行った。対象は脳腫瘍、眼窩腫瘍、頭頚部腫瘍、肺癌、食道癌、乳癌、心腫瘍、肝癌、膵臓癌、腎癌、膀胱癌、大腸癌、子宮頚癌、卵巣癌、骨軟部腫瘍当の多岐にわたった腫瘍である。検査にはFDGあるいは11C-メチオニンが用いられた。68Ge線源を用いた通常のPET検査を施行した直後に別室のPET-CTに移動し、続けて検査を施行した。得られた画像を視覚的に比較すると共に、腫瘍部および周辺正常組織にROIを設定し値を比較した。PET-CTの方がノイズの少ない良好な画像が得られる傾向を認めた。ROI値もややPET-CTが高く出る傾向を認めたが、臨床上は問題ない程度と判断された。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第43回 日本核医学会総会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"吉川, 京燦"}],"nameIdentifiers":[{"nameIdentifier":"597135","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐合, 賢治"}],"nameIdentifiers":[{"nameIdentifier":"597136","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田村, 克巳"}],"nameIdentifiers":[{"nameIdentifier":"597137","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山田, 実"}],"nameIdentifiers":[{"nameIdentifier":"597138","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松野, 典代"}],"nameIdentifiers":[{"nameIdentifier":"597139","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"張, 宏"}],"nameIdentifiers":[{"nameIdentifier":"597140","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"須原, 哲也"}],"nameIdentifiers":[{"nameIdentifier":"597141","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木, 和年"}],"nameIdentifiers":[{"nameIdentifier":"597142","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"棚田, 修二"}],"nameIdentifiers":[{"nameIdentifier":"597143","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"辻井, 博彦"}],"nameIdentifiers":[{"nameIdentifier":"597144","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐々木, 康人"}],"nameIdentifiers":[{"nameIdentifier":"597145","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉川 京燦","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"597146","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐合 賢治","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"597147","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田村 克巳","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"597148","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山田 実","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"597149","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松野 典代","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"597150","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"張 宏","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"597151","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"須原 哲也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"597152","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木 和年","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"597153","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"棚田 修二","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"597154","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"辻井 博彦","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"597155","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐々木 康人","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"597156","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"PET-CT画像と68Ge線源による吸収補正PE画像との比較","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"PET-CT画像と68Ge線源による吸収補正PE画像との比較"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-11-04"},"publish_date":"2003-11-04","publish_status":"0","recid":"60050","relation_version_is_last":true,"title":["PET-CT画像と68Ge線源による吸収補正PE画像との比較"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:58:04.164185+00:00"}