{"created":"2023-05-15T14:43:48.311202+00:00","id":59926,"links":{},"metadata":{"_buckets":{"deposit":"d912c210-f87a-4a8e-a050-be57899760e8"},"_deposit":{"created_by":1,"id":"59926","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"59926"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00059926","sets":["10:29"]},"author_link":["596076","596073","596081","596074","596075","596078","596077","596079","596071","596072","596080"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2003-09-27","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"[目的]voxel内の脳実質とCSFを、T2値のちがい(脳実質80ms、 CSF500ms)を利用して分離する1)ため、その基礎実験として、水phantomを用いてT2値の推定を行った。[方法]測定にはSigna LX 1.5T(GE)を用いた。0.125ml, 1ml, 3.375ml, 8mlの各voxelに対し、TR3000msでTEを30msから1000msまで変え、水抑制をしないPRESS法により水phantomのMRS信号を測定した。T2値の計算には、水スペクトルの絶対値を積分した値を用いた。また比較のために、PRESS法で選択した領域を256*128サンプルでTEを変えて撮像し、T2値を推定した。raw dataからの画像再構成にはIDL(Research Systems, Inc.)、T2値の推定にはMathematica(Wolfram Research)を用いた。[結果] voxelが大きい時のMRS信号はTEの増加とともに急速に減衰し、指数曲線にはのらなかった。推定したT2値も小さかった。画像信号はTEの増加とともに指数的に減衰しており、推定したT2値はMRSで得た値より大きくなった。複素画像の画素毎に信号を複素加算して後から絶対値を取ると、MRSと等価な信号になる。この信号から計算したT2値はMRSで得られたT2値とほぼ同じになった。 [結論] 渦電流で生じるような、時間とともに変動する磁場の影響は、PRESSなどのSEでは回復できない。 MRSは選択するvoxelが大きいので、voxel内の位相分布の影響で信号強度は大きく減衰する。このため、MRS信号から推定したT2値に定量性は期待できない。画像からT2値を推定する方法は、測定時間は長いが精度は良い。\n1) T.Ernst, R.Kreis and B.D.Ross, JMR B 102, 1-8 (1993)","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第31回日本磁気共鳴医学会大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"吉留, 英二"}],"nameIdentifiers":[{"nameIdentifier":"596071","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田中, 陽子"}],"nameIdentifiers":[{"nameIdentifier":"596072","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小畠, 隆行"}],"nameIdentifiers":[{"nameIdentifier":"596073","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"池平, 博夫"}],"nameIdentifiers":[{"nameIdentifier":"596074","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"棚田, 修二"}],"nameIdentifiers":[{"nameIdentifier":"596075","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松田, 豪"}],"nameIdentifiers":[{"nameIdentifier":"596076","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉留 英二","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"596077","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田中 陽子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"596078","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小畠 隆行","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"596079","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"池平 博夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"596080","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"棚田 修二","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"596081","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"MRS測定への応用を考慮したT2値測定方法に関する考察","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"MRS測定への応用を考慮したT2値測定方法に関する考察"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-08-28"},"publish_date":"2003-08-28","publish_status":"0","recid":"59926","relation_version_is_last":true,"title":["MRS測定への応用を考慮したT2値測定方法に関する考察"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:59:29.346218+00:00"}