{"created":"2023-05-15T14:43:47.424521+00:00","id":59906,"links":{},"metadata":{"_buckets":{"deposit":"09563db4-ee6e-44d4-b41c-7683077f708b"},"_deposit":{"created_by":1,"id":"59906","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"59906"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00059906","sets":["10:29"]},"author_link":["595948","595950","595951","595949"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2001-06-14","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"An electrostatic accelerator, Tandetron (Model 4117MC, High Voltage \nEngineering Europe Co.) was installed in National Institute of Radiological \nSciences (NIRS) for PIXE (Particle Induced X-ray Emission) analysis in \n1999. The accelerating voltage is 0.4 to 1.7MV, and the maximum beam \ncurrent is 5microA at 3.4MeV. This system has three beam ports for \ndifferent types of PIXE analysis, conventional, micro-beam and in-air. \nNormal PIXE line has two types of X-ray detecting device, Si (Li) and \nCdZnTe detectors detectable for elements from Na (Z=11) to U (Z=92). \nFifteen samples can semi automatically be measured at one time with the \noptical beam size from 0.5 to 2.0 mm at 100 nA of the beam current. A \nquadruple triplet magnet (Model OM2000, Oxford Micro beams, Ltd.) attached \nto the other beam port produces a proton micro-beam of the square shape \nless than 1micron x 1micron. Micro-beam \nscanning PIXE analysis is carried out with this beam at 50pA current and \nscanning area up to 2.0mm square. The in-air PIXE analysis is performed \nusing the third beam port.\nIn this paper, we introduce micro-PIXE scanning system showing the ability \nto draw elemental maps in a spatial resolution of about 1 µm with \nanalyses of fish scale, fish otolith, crocus pollen and micro organisms. \nFine ring structure of a fish scale was observed using elemental mapping \nwith proton micro-beam scanning. Pollen was analyzed as one example of \nsingle cell to demonstrate the elemental distribution. Fish scale and \notolith seem to be a kind of time recorder like tree rings. And the \nelemental composition reflects the living condition. Therefore, fish scale \nand otolith are possible to be used as a biological indicator.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"3rd International Symposium on Nuclear Analytical Chemistry (NAC-III)","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yukawa, Masae"}],"nameIdentifiers":[{"nameIdentifier":"595948","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Imaseki, Hitoshi"}],"nameIdentifiers":[{"nameIdentifier":"595949","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"湯川 雅枝","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"595950","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関 等","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"595951","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Introduction of PIXE anallysis system in National Institute of Radiological Sciences","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Introduction of PIXE anallysis system in National Institute of Radiological Sciences"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-08-26"},"publish_date":"2003-08-26","publish_status":"0","recid":"59906","relation_version_is_last":true,"title":["Introduction of PIXE anallysis system in National Institute of Radiological Sciences"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:59:42.749503+00:00"}