{"created":"2023-05-15T14:43:30.592153+00:00","id":59595,"links":{},"metadata":{"_buckets":{"deposit":"27d0b5ad-1a6c-490d-9ffb-05583a16cef1"},"_deposit":{"created_by":1,"id":"59595","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"59595"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00059595","sets":["10:29"]},"author_link":["593044","593047","593049","593046","593045","593048"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2002-09-20","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"目的)長期宇宙滞在時の高LET放射線による造血系への影響をC3Hマウスを用いて、HIMACによる重粒子線照射により調べた。\n実験方法)8〜10週令C3Hマウス(雄、雌)を用い、HIMACにより高LET放射線の全身照射を行った。照射核種は炭素(290MeV/n, 13keV/u)、ネオン(400 MeV/n, 31 keV/u)、シリコン(490 MeV/n, 55KeV/u)、アルゴン(500 MeV/n, 85keV/u )、鉄(500 MeV/n, 200keV/u)を用い、1Gy、3Gyの線量を照射後、約8日までの造血系機能と脾臓の組織重量変化を経時的に測定した。\n結果と考察)脾臓重量の経時変化には核種依存性がほとんど見られず、1Gy照射後1.5日で約60%、3Gy照射後2.5日で約40%まで減少しその後一週間でゆっくり回復した。白血球数は、炭素線では、1Gy照射後1.5日で50%、3Gy照射後30%に減少したが、アルゴン、鉄線では1Gy照射後40%、3Gy照射後で20%まで減少した。骨髄中の単球・顆粒球系造血幹細胞(GMCFU)は、炭素線1Gy照射後1.5日では鉄線より低く約40%まで減少し、3Gy照射後1.5日では鉄線とほぼ同じ5%まで減少した。照射後の回復過程は鉄線の方が早く、7.5日後において、約40%まで回復したのに対し、炭素線では約10%までしか回復しなかった。また、脾臓中の単球・顆粒球系造血幹細胞(GMCFU)も骨髄GMCFUと同様な傾向を示し、鉄線の方が早い回復をしました。また、脾臓GMCFUでは、照射後2.5日までは雌雄差が認められ、雌の方が雄に比べ抵抗性を示した。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"日本放射線影響学会第45回大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"野島, 久美恵"}],"nameIdentifiers":[{"nameIdentifier":"593044","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"劉, 翠華"}],"nameIdentifiers":[{"nameIdentifier":"593045","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長岡, 俊治"}],"nameIdentifiers":[{"nameIdentifier":"593046","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野島 久美恵","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"593047","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"劉 翠華","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"593048","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長岡 俊治","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"593049","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"高LET放射線によるマウス造血系への影響","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"高LET放射線によるマウス造血系への影響"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-03-16"},"publish_date":"2003-03-16","publish_status":"0","recid":"59595","relation_version_is_last":true,"title":["高LET放射線によるマウス造血系への影響"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:03:07.778310+00:00"}