{"created":"2023-05-15T14:43:30.329168+00:00","id":59589,"links":{},"metadata":{"_buckets":{"deposit":"6b29d688-c2ca-4aae-b959-bbb2dcf3abb0"},"_deposit":{"created_by":1,"id":"59589","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"59589"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00059589","sets":["10:29"]},"author_link":["592979","592989","592986","592977","592988","592978","592982","592984","592983","592985","592980","592987","592976","592981"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2001-03-01","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":" 固体飛跡検出器の飛跡生成感度を制御することを目的として、混合比率の異なる何種類課のCR-39とDAPの共重合体樹脂を調整した。それらの樹脂を放医研 HIMACを用いて数種類のイオンで照射した。エッチング後、樹脂表面に生成したエッチピットを光学顕微鏡を用いて観察した。共重合体樹脂は CR-39と DAP 樹脂の中間的な性質を示した。CR-39 と DAPの共重合体樹脂の調整は個体飛跡検出器の感度制御の可能性を示した。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"日本原子力学会 2002年春の大会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小口, 靖弘"}],"nameIdentifiers":[{"nameIdentifier":"592976","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤村, 建策"}],"nameIdentifiers":[{"nameIdentifier":"592977","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鶴田, 隆雄"}],"nameIdentifiers":[{"nameIdentifier":"592978","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小西, 輝昭"}],"nameIdentifiers":[{"nameIdentifier":"592979","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松本, 健一"}],"nameIdentifiers":[{"nameIdentifier":"592980","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安田, 仲宏"}],"nameIdentifiers":[{"nameIdentifier":"592981","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山本, 幹男"}],"nameIdentifiers":[{"nameIdentifier":"592982","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小口 靖弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"592983","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤村 建策","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"592984","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鶴田 隆雄","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"592985","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小西 輝昭","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"592986","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松本 健一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"592987","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安田 仲宏","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"592988","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山本 幹男","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"592989","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"感度制御可能な固体飛跡検出器の開発(?)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"感度制御可能な固体飛跡検出器の開発(?)"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-02-27"},"publish_date":"2003-02-27","publish_status":"0","recid":"59589","relation_version_is_last":true,"title":["感度制御可能な固体飛跡検出器の開発(?)"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:03:11.689570+00:00"}