{"created":"2023-05-15T14:43:30.106608+00:00","id":59584,"links":{},"metadata":{"_buckets":{"deposit":"02ff2abb-c191-40b0-a489-9d08c0265cd9"},"_deposit":{"created_by":1,"id":"59584","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"59584"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00059584","sets":["10:29"]},"author_link":["592928","592930","592929","592927"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2001-02-24","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":" Delayed luminescence is a weak light in the visible spectrum region, which decays hyperbolically after exposure to external light illumination of the sample. It has a diagnostic value, although its fundamental properties are not well understood yet. We constructed a chopper system, which allows the illumination of the object with 100 Hz pulses of light. We collected the DL emission data on cooled CCD for 2D imaging between pulses\n","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第11回生命情報科学会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Parkhomtchouk, Dmitri"}],"nameIdentifiers":[{"nameIdentifier":"592927","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamamoto, Mikio"}],"nameIdentifiers":[{"nameIdentifier":"592928","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"デミトリ パルホムチュク","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"592929","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山本 幹男","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"592930","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"2D Cooled CCD Imaging of Delayed Luminescence","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"2D Cooled CCD Imaging of Delayed Luminescence"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-02-21"},"publish_date":"2003-02-21","publish_status":"0","recid":"59584","relation_version_is_last":true,"title":["2D Cooled CCD Imaging of Delayed Luminescence"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:03:14.977730+00:00"}