{"created":"2023-05-15T14:43:11.761247+00:00","id":59180,"links":{},"metadata":{"_buckets":{"deposit":"0ccde3f1-db3c-4731-84d4-e2b68bddf66f"},"_deposit":{"created_by":1,"id":"59180","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"59180"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00059180","sets":["10:29"]},"author_link":["589259","589252","589246","589251","589260","589249","589250","589254","589256","589258","589248","589255","589257","589247","589253"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2001-04-06","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"4月より開院する兵庫県立粒子線医療センターの190MeV陽子線および320MeV炭素線の生物効果比を同医療センターの4MeVライナックX線の結果と比較して求めた。実験は、陽子線、炭素線とも6cmSOBPビームを使用した。腸管はそれぞれについて、入射部1点、SOBPの中心1点、SOBP入り口より5っm1点、SOBP終点より5mm手前の4ポイントについて行った。マウス小腸クリプトの生残数よりRBEを求めると陽子線は1〜1.08であり、炭素線はSOBP内では1.53〜1.86\nであった。また、炭素線については、皮膚反応による分割照射効果を4日間の分割照射により皮膚スコアをエンドポイントとして4MevライナックX線の結果と比較してRBEを求めたので報告する。","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"野島, 久美恵"}],"nameIdentifiers":[{"nameIdentifier":"589246","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"香川, 一史"}],"nameIdentifiers":[{"nameIdentifier":"589247","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"矢能, 稔啓"}],"nameIdentifiers":[{"nameIdentifier":"589248","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安藤, 興一"}],"nameIdentifiers":[{"nameIdentifier":"589249","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"清水, 勝一"}],"nameIdentifiers":[{"nameIdentifier":"589250","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤城, 卓"}],"nameIdentifiers":[{"nameIdentifier":"589251","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"井田, 亮二"}],"nameIdentifiers":[{"nameIdentifier":"589252","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"村上, 昌雄"}],"nameIdentifiers":[{"nameIdentifier":"589253","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"菱川, 良夫"}],"nameIdentifiers":[{"nameIdentifier":"589254","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野島 久美恵","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"589255","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"香川 一史","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"589256","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安藤 興一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"589257","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤城 卓","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"589258","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"村上 昌雄","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"589259","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"菱川 良夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"589260","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"兵庫県粒子線医療センター陽子線・炭素線の生物効果(in vivo)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"兵庫県粒子線医療センター陽子線・炭素線の生物効果(in vivo)"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2002-06-12"},"publish_date":"2002-06-12","publish_status":"0","recid":"59180","relation_version_is_last":true,"title":["兵庫県粒子線医療センター陽子線・炭素線の生物効果(in vivo)"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:07:48.144153+00:00"}