{"created":"2023-05-15T14:43:05.766939+00:00","id":59045,"links":{},"metadata":{"_buckets":{"deposit":"1426d617-f5b5-48a3-bbd7-97dc7c61d096"},"_deposit":{"created_by":1,"id":"59045","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"59045"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00059045","sets":["10:29"]},"author_link":["588191","588189","588190","588184","588185","588188","588186","588187"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2001-05-25","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":" 放医研において,ラドンを専門に研究するための研究施設が建設され,現在は本格的実験を行うために実験設備の調整を行っている一方,ホットランに向けて,ラドンのバックグランドレベルを測定している。そこで,本発表ではその測定結果について報告する。測定の結果、外気のラドン濃度が10Bq/m3程度以下である時、管理区域内の空調が停止した場合、実験室内において、ラドン線源が無くてもラドン濃度が100Bq/m3程度まで上昇する。さらに、実験室地下ピット内では、700Bq/m3程度であることが明らかとなった。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"日本保健物理学会第35回研究発表会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"一坪, 宏和"}],"nameIdentifiers":[{"nameIdentifier":"588184","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山田, 裕司"}],"nameIdentifiers":[{"nameIdentifier":"588185","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小泉, 彰"}],"nameIdentifiers":[{"nameIdentifier":"588186","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"下, 道國"}],"nameIdentifiers":[{"nameIdentifier":"588187","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"一坪 宏和","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"588188","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山田 裕司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"588189","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小泉 彰","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"588190","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"下 道國","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"588191","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"研究施設内におけるラドン濃度−バックグランドレベル−","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"研究施設内におけるラドン濃度−バックグランドレベル−"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2002-06-04"},"publish_date":"2002-06-04","publish_status":"0","recid":"59045","relation_version_is_last":true,"title":["研究施設内におけるラドン濃度−バックグランドレベル−"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:09:21.527039+00:00"}