{"created":"2023-05-15T14:42:56.965215+00:00","id":58846,"links":{},"metadata":{"_buckets":{"deposit":"a5a09307-89a9-4af6-8539-e6f70bc97aff"},"_deposit":{"created_by":1,"id":"58846","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"58846"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00058846","sets":["11"]},"author_link":["586668","586667","586664","586662","586669","586663","586665","586666"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-08","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"47","bibliographicPageStart":"44","bibliographic_titles":[{"bibliographic_title":"クリーンエネルギー"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"熱化学水素製造ISプロセスの一工程であるブンゼン反応(2H2O+SO2+I2→H2SO4+2HI)の熱効率向上を目指し、カチオン交換膜を用いた専用のブンゼン反応器を開発した。放射線グラフト重合法で作製したカチオン交換膜を用いてブンゼン反応試験を行ったとき、既存の市販膜の場合よりも反応過電圧を低減できた。","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"野村幹弘"}],"nameIdentifiers":[{"nameIdentifier":"586662","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今林慎一郎"}],"nameIdentifiers":[{"nameIdentifier":"586663","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"澤田, 真一"}],"nameIdentifiers":[{"nameIdentifier":"586664","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"八巻, 徹也"}],"nameIdentifiers":[{"nameIdentifier":"586665","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田中伸幸"}],"nameIdentifiers":[{"nameIdentifier":"586666","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"久保真治"}],"nameIdentifiers":[{"nameIdentifier":"586667","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"澤田 真一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"586668","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"八巻 徹也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"586669","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"高効率な水素製造を可能にするイオン交換膜型ブンゼン反応器の開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"高効率な水素製造を可能にするイオン交換膜型ブンゼン反応器の開発"}]},"item_type_id":"10004","owner":"1","path":["11"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-03-22"},"publish_date":"2018-03-22","publish_status":"0","recid":"58846","relation_version_is_last":true,"title":["高効率な水素製造を可能にするイオン交換膜型ブンゼン反応器の開発"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:11:32.072747+00:00"}