{"created":"2023-05-15T14:42:46.106904+00:00","id":58602,"links":{},"metadata":{"_buckets":{"deposit":"2f5e75bc-ca7e-454d-825c-72ceee23ca14"},"_deposit":{"created_by":1,"id":"58602","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"58602"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00058602","sets":["11"]},"author_link":["585612","585611"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-11","bibliographicIssueDateType":"Issued"},"bibliographic_titles":[{"bibliographic_title":"PET用放射性薬剤開発の最新動向"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":" 陽電子断層撮影法(以下,PET)が研\n究上の1 ツールにとどまらず,がん診断や\n脳機能検査などを目的に,日々の臨床現\n場で広く利用されていることは周知のとお\nりである。PET 画像が与える視覚的な情\n報は,供与する医療の質を高めるとともに,\n受診者が自らの心身状態を把握する大き\nな助けにもなっていると推測される。\n PET 用放射性薬剤について実験室的な\n説明が許されるならば,化合物(薬剤)と\nしての化学・生物学的な性質・挙動と,\nポジトロンならびに511 keV の消滅放射\n線を放出する,という異なる2つの特性が\n同一物質中に内在していると表現できる。\nわれわれは,前者の特異性によって評価\nしたい生体機能や疾病を限定し(ターゲッ\nティング),後者によって体外からの計測・\n確認(シグナリング)を可能にしている。\n互いに独立させることもできる両特性は,\n放射性薬剤の分子設計に大きな自由度を\n与え,単なる構造上の差異だけでなく,薬\n理・薬物動態を意味する機能性分子の構\n築に貢献する。そして,この自由度こそが\n研究開発上の興味と動機の本質になって\nいる。","subitem_description_type":"Abstract"}]},"item_10004_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"月刊インナービジョン"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"永津, 弘太郎"}],"nameIdentifiers":[{"nameIdentifier":"585611","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"永津 弘太郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"585612","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"PET用放射性薬剤開発の最新動向","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"PET用放射性薬剤開発の最新動向"}]},"item_type_id":"10004","owner":"1","path":["11"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-12-28"},"publish_date":"2015-12-28","publish_status":"0","recid":"58602","relation_version_is_last":true,"title":["PET用放射性薬剤開発の最新動向"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:14:13.888643+00:00"}