{"created":"2023-05-15T14:42:44.650622+00:00","id":58569,"links":{},"metadata":{"_buckets":{"deposit":"4c97a8e0-f4c9-47d1-b2b9-be4d036d07c4"},"_deposit":{"created_by":1,"id":"58569","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"58569"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00058569","sets":["11"]},"author_link":["585462","585463"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"32","bibliographicPageStart":"29","bibliographicVolumeNumber":"36","bibliographic_titles":[{"bibliographic_title":"基礎老化研究"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"放射線は、生体内で水を電離してヒドロキシルラジカル(・OH)を生成し、更にその後の反応を介してその他の活性酸素種を生成する。それによって生体に酸化ストレスを与えるのであるが、放射線による活性酸素の生成量はどの程度なのだろうか。本稿ではX線で生じる・OHについてその量と分布を調べた。","subitem_description_type":"Abstract"}]},"item_10004_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本基礎老化学会"}]},"item_10004_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0912-8921","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"松本, 謙一郎"}],"nameIdentifiers":[{"nameIdentifier":"585462","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松本 謙一郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"585463","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"X線により生じるヒドロキシルラジカルの量とその分布の解析","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"X線により生じるヒドロキシルラジカルの量とその分布の解析"}]},"item_type_id":"10004","owner":"1","path":["11"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-08-15"},"publish_date":"2015-08-15","publish_status":"0","recid":"58569","relation_version_is_last":true,"title":["X線により生じるヒドロキシルラジカルの量とその分布の解析"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:14:34.888376+00:00"}