{"created":"2023-05-15T14:42:39.387878+00:00","id":58452,"links":{},"metadata":{"_buckets":{"deposit":"67ebcad2-5a79-4245-aa6c-9d1d0c661139"},"_deposit":{"created_by":1,"id":"58452","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"58452"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00058452","sets":["11"]},"author_link":["584916","584918","584917","584919","584915"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013-03","bibliographicIssueDateType":"Issued"},"bibliographic_titles":[{"bibliographic_title":"実践 マイクロセレクトロンHDRを使用した高線量率密封小線源治療ガイダンス2013"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"マイクロセレクトロンHDRを使用した高線量率密封小線源治療における実践的ガイダンス","subitem_description_type":"Abstract"}]},"item_10004_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"株式会社千代田テクノル"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"土器屋卓志"}],"nameIdentifiers":[{"nameIdentifier":"584915","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"萬篤憲"}],"nameIdentifiers":[{"nameIdentifier":"584916","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鶴岡, 伊知郎"}],"nameIdentifiers":[{"nameIdentifier":"584917","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"584918","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鶴岡 伊知郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"584919","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"実践 マイクロセレクトロンHDRを使用した高線量率密封小線源治療ガイダンス2013","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"実践 マイクロセレクトロンHDRを使用した高線量率密封小線源治療ガイダンス2013"}]},"item_type_id":"10004","owner":"1","path":["11"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-06-03"},"publish_date":"2014-06-03","publish_status":"0","recid":"58452","relation_version_is_last":true,"title":["実践 マイクロセレクトロンHDRを使用した高線量率密封小線源治療ガイダンス2013"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:15:47.696328+00:00"}