{"created":"2023-05-15T14:42:37.128028+00:00","id":58403,"links":{},"metadata":{"_buckets":{"deposit":"5363fc2e-80d7-4255-9fe9-14ceaf3f4661"},"_deposit":{"created_by":1,"id":"58403","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"58403"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00058403","sets":["11"]},"author_link":["584580","584584","584581","584582","584583","584585","584579","584576","584577","584578","584575"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-12","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"110","bibliographicPageStart":"100","bibliographicVolumeNumber":"30","bibliographic_titles":[{"bibliographic_title":"医学物理"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"国内でのリニアック出力線量調査について、WEBデータから、歴史的な経緯と今後について概説した。1985年~1996年の黎明期から始まり、1997年から2002年の土台形成期で、継続可能な調査システムの模索がなされた。2003年から2008年はシステム立ち上げ期で、組織的な取り組みが開始されている。厚生労働科学研究費補助金池田班では、郵送/訪問による線量測定調査が実施され、またこれに協力する形などで、地域の訪問調査が実施されている。ここで実施された郵送調査は、班研究から放射線医学総合研究所に引き継がれ、必要な改良、確認作業を行った後、財団の出力線量測定事業として実施されるようになった。放射線医学総合研究所では、吸収線量の基準を放医研のコバルトγ線(2次標準場)とし、がん診療拠点病院を対象に106施設192ビームについて測定を行い、平均値+0.3%、標準偏差1.3%(±3%以内に95%のビーム)をえた。偏差が4%を超えた施設に対して、その原因を確認し、2回目の調査を行ったが、すべて改善している。","subitem_description_type":"Abstract"}]},"item_10004_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本医学物理学会"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"池田, 恢"}],"nameIdentifiers":[{"nameIdentifier":"584575","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐方, 周防"}],"nameIdentifiers":[{"nameIdentifier":"584576","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福村, 明史"}],"nameIdentifiers":[{"nameIdentifier":"584577","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"齋藤, 則生"}],"nameIdentifiers":[{"nameIdentifier":"584578","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水野, 秀之"}],"nameIdentifiers":[{"nameIdentifier":"584579","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"新保, 宗史"}],"nameIdentifiers":[{"nameIdentifier":"584580","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"池田 恢","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"584581","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐方 周防","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"584582","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福村 明史","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"584583","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水野 秀之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"584584","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"新保 宗史","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"584585","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"線量計のトレーサビリティと治療線量の統一化","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"線量計のトレーサビリティと治療線量の統一化"}]},"item_type_id":"10004","owner":"1","path":["11"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-02-04"},"publish_date":"2014-02-04","publish_status":"0","recid":"58403","relation_version_is_last":true,"title":["線量計のトレーサビリティと治療線量の統一化"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:16:17.724955+00:00"}