{"created":"2023-05-15T14:42:00.513670+00:00","id":57587,"links":{},"metadata":{"_buckets":{"deposit":"a93322d6-cb7f-4296-9e05-b7314d96bd97"},"_deposit":{"created_by":1,"id":"57587","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"57587"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00057587","sets":["11"]},"author_link":["580818","580819","580814","580816","580820","580817","580815","580813"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"13","bibliographicPageStart":"11","bibliographicVolumeNumber":"52","bibliographic_titles":[{"bibliographic_title":"放射線科学"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"X線照射装置TITAN320型は、前X線発生装置PANTAK HF-320型の後継機として2008年3月上旬、X線棟第3照射室に設置された。装置更新に伴い、TITAN-320型の線量測定を実施した。X線管焦点と照射台間距離(Focus Sample Distance以下、FSD)を変更することができ、空気カーマ率3.51〜0.21 Gy/minの範囲で照射が可能である。付属されている高線量照射用回転テーブルを照射台に設置すると、5.00 Gy/min以上(FSD235mm、照射野100 mm)での照射が可能であることが確認された。","subitem_description_type":"Abstract"}]},"item_10004_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0441-2540","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"三井, 大輔"}],"nameIdentifiers":[{"nameIdentifier":"580813","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酢屋, 徳啓"}],"nameIdentifiers":[{"nameIdentifier":"580814","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川, 剛弘"}],"nameIdentifiers":[{"nameIdentifier":"580815","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"磯, 浩之"}],"nameIdentifiers":[{"nameIdentifier":"580816","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関, 等"}],"nameIdentifiers":[{"nameIdentifier":"580817","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酢屋 徳啓","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"580818","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川 剛弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"580819","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関 等","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"580820","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"X線発生装置TITAN-320型における線量測定結果","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"X線発生装置TITAN-320型における線量測定結果"}]},"item_type_id":"10004","owner":"1","path":["11"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-07-02"},"publish_date":"2009-07-02","publish_status":"0","recid":"57587","relation_version_is_last":true,"title":["X線発生装置TITAN-320型における線量測定結果"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:25:28.318235+00:00"}