{"created":"2023-05-15T14:41:59.664267+00:00","id":57568,"links":{},"metadata":{"_buckets":{"deposit":"9ff22527-1897-4d61-855e-0339c5faac4a"},"_deposit":{"created_by":1,"id":"57568","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"57568"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00057568","sets":["11"]},"author_link":["580692","580693","580697","580694","580696","580695"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-12","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"53","bibliographicPageEnd":"34","bibliographicPageStart":"32","bibliographic_titles":[{"bibliographic_title":"医療放射線防護 NEWSLETTER"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"国際放射線単位測定委員会 (ICRU: International Commission on Radiation Units and Measurements)は、これまで放射線治療分野での線量測定と線量表記法に関するレポートを種々刊行してきたが、陽子線治療に関しても約10年前にICRUレポート59 Clinical Proton Dosimetry Part 1: Beam Production, Beam Delivery and Measurement of Absorbed Dose (1998) を刊行している。今回、線量測定に関する新たな知見を追加、改訂し、さらに生物学的分野と処方線量に関する記述も併せ、包括的文書として、ICRUレポート78 「陽子線治療の処方、記録、報告」(ICRU Report 78, Prescribing, Recording, and Reporting Proton-Beam Therapy, Journal of the ICRU 7(2), 2007) が発刊された(図1)。このレポートは、ICRUと国際原子力機関(IAEA)との共同レポートとなっている。章の構成を表1に示すが、内容は、生物学的側面、ビーム生成、線量測定、治療計画、QAにわたる全般的解説があり、それに基づき線量処方、記録、報告の方法を提示している。","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"立崎, 英夫"}],"nameIdentifiers":[{"nameIdentifier":"580692","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"兼松, 伸幸"}],"nameIdentifiers":[{"nameIdentifier":"580693","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"辻井, 博彦"}],"nameIdentifiers":[{"nameIdentifier":"580694","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"立崎 英夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"580695","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"兼松 伸幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"580696","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"辻井 博彦","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"580697","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ICRUレポート78 「陽子線治療の処方、記録、報告」について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ICRUレポート78 「陽子線治療の処方、記録、報告」について"}]},"item_type_id":"10004","owner":"1","path":["11"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-05-22"},"publish_date":"2009-05-22","publish_status":"0","recid":"57568","relation_version_is_last":true,"title":["ICRUレポート78 「陽子線治療の処方、記録、報告」について"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:25:41.079209+00:00"}