{"created":"2023-05-15T14:41:50.349901+00:00","id":57361,"links":{},"metadata":{"_buckets":{"deposit":"445dc8eb-4597-4d09-9d1a-04cb0418c1fc"},"_deposit":{"created_by":1,"id":"57361","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"57361"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00057361","sets":["11"]},"author_link":["579735","579736","579733","579738","579732","579731","579730","579734","579737","579729"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"63","bibliographicPageStart":"57","bibliographicVolumeNumber":"12","bibliographic_titles":[{"bibliographic_title":"医用標準線量"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"放医研に設置されているソフテックス株式会社製M-70-WE特型X線発生装置は、照射用として最大管電圧が70kVのX線が得られる。 今回放射線防護薬の研究として、マウス皮膚の放射線障害と防護薬の研究の利用のため、軟X線照射場のドシメトリーを行った。浅い皮膚面の傷害に対する影響を研究するため、30kVpX線を選定して特性を検討し照射場を決定した。照射管電圧の決定、付加フィルター零とPMMA0.5mm通過後の半価層、照射ビームの実効エネルギー、照射野の線量分布、深部線量分布の検討、測定電離箱の校正定数、マウス照射ケージの決定、マウス皮膚における水吸収線量の決定、など測定および検討結果について述べる。","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"平岡, 武"}],"nameIdentifiers":[{"nameIdentifier":"579729","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三井, 大輔"}],"nameIdentifiers":[{"nameIdentifier":"579730","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川, 剛弘"}],"nameIdentifiers":[{"nameIdentifier":"579731","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"濱野, 毅"}],"nameIdentifiers":[{"nameIdentifier":"579732","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮原, 信幸"}],"nameIdentifiers":[{"nameIdentifier":"579733","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平岡 武","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"579734","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三井 大輔","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"579735","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川 剛弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"579736","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"濱野 毅","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"579737","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮原 信幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"579738","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"軟X線の線量測定","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"軟X線の線量測定"}]},"item_type_id":"10004","owner":"1","path":["11"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-02-08"},"publish_date":"2008-02-08","publish_status":"0","recid":"57361","relation_version_is_last":true,"title":["軟X線の線量測定"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:27:58.215456+00:00"}