{"created":"2023-05-15T14:41:46.684064+00:00","id":57278,"links":{},"metadata":{"_buckets":{"deposit":"c18b2043-29e9-48d6-955a-ad32794c8a50"},"_deposit":{"created_by":1,"id":"57278","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"57278"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00057278","sets":["11"]},"author_link":["579204","579211","579207","579209","579212","579206","579203","579205","579210","579208"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-04","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"21","bibliographicPageStart":"13","bibliographicVolumeNumber":"12","bibliographic_titles":[{"bibliographic_title":"医用標準線量"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"放医研第1ガンマ線照射棟は1960年3384Ci(125TBq)の60Co線源が導入されたのが始まりである。 \n 照射筒内で円筒状等間隔に配置された6本の60Co線源(全放射能111Tbq)の線源照射筒内と線源中心軸の水吸収線量を測定した。中心軸上に基準点を設定し、絶対線量は基準電離箱としている0.6mlのファーマ電離箱にて測定した。 また、中心軸の線量は位置分解能を高めるため、0.2mlのファーマ電離箱で測定した。\n さらに、照射筒内のラジアル線量分布はラジオクロミックフイルムの光学濃度分布から算定した。","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"平岡, 武"}],"nameIdentifiers":[{"nameIdentifier":"579203","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三井, 大輔"}],"nameIdentifiers":[{"nameIdentifier":"579204","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川, 剛弘"}],"nameIdentifiers":[{"nameIdentifier":"579205","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"濱野, 毅"}],"nameIdentifiers":[{"nameIdentifier":"579206","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関, 等"}],"nameIdentifiers":[{"nameIdentifier":"579207","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平岡 武","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"579208","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三井 大輔","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"579209","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川 剛弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"579210","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"濱野 毅","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"579211","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関 等","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"579212","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"円筒状に配置した111TBq60Co線源の線量測定","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"円筒状に配置した111TBq60Co線源の線量測定"}]},"item_type_id":"10004","owner":"1","path":["11"],"pubdate":{"attribute_name":"公開日","attribute_value":"2007-06-04"},"publish_date":"2007-06-04","publish_status":"0","recid":"57278","relation_version_is_last":true,"title":["円筒状に配置した111TBq60Co線源の線量測定"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:28:53.431604+00:00"}