{"created":"2023-05-15T14:41:07.344059+00:00","id":56392,"links":{},"metadata":{"_buckets":{"deposit":"89422b8f-fa83-4e5b-aaf1-4e47d1cf276a"},"_deposit":{"created_by":1,"id":"56392","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"56392"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00056392","sets":["11"]},"author_link":["575442","575441","575440","575443"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"16","bibliographicPageStart":"11","bibliographicVolumeNumber":"14","bibliographic_titles":[{"bibliographic_title":"Biomedical Research on Trace Elements"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Abstract Particle Induced X-ray Emission(PIXE)analysis is one of the analytical methods for elements. PIXE has high sensitivity, multi-elemental and non-destructive characteristics and the advantage of micro-beam scanning ability on the sample surface. In 1999, micro-beam scanning PIXE system was installed at the National Institute of Radiological Sciences (NIRS). The system allowed multi elemental mapping on 2mm x 2mm areas of small samples such as fish scales, small fish eyes, pollen etc. with a special resolution of about 1mu m with accelerated proton micro-beams produced by an electrostatic accelerator, Tandetron (Model 4117MC, High Voltage Engineering Europe Co.) and a micro-beam scanning system (Model OM2000, Oxford Micro Beams, Ltd.).\n Fine ring structure of a fish scale was observed with P and Ca maps. Pollen was examined to ability of the system to draw elemental distribution maps of singles cell. The distribution of elements in a thin section of Medaka eye was investigated in connection with Scanning Transmission Ion Microscopy (STIM).","subitem_description_type":"Abstract"}]},"item_10004_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0916-717X","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yukawa, Masae"}],"nameIdentifiers":[{"nameIdentifier":"575440","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Imaseki, Hitoshi"}],"nameIdentifiers":[{"nameIdentifier":"575441","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"湯川 雅枝","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"575442","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関 等","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"575443","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Imaging of elemental distribution in the small area of biological samples- micro-PIXE analysis","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Imaging of elemental distribution in the small area of biological samples- micro-PIXE analysis"}]},"item_type_id":"10004","owner":"1","path":["11"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-05-16"},"publish_date":"2003-05-16","publish_status":"0","recid":"56392","relation_version_is_last":true,"title":["Imaging of elemental distribution in the small area of biological samples- micro-PIXE analysis"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:38:45.910296+00:00"}