{"created":"2023-05-15T14:40:52.906358+00:00","id":56063,"links":{},"metadata":{"_buckets":{"deposit":"9040816c-c1ef-43ee-906a-cb6fb451d44f"},"_deposit":{"created_by":1,"id":"56063","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"56063"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00056063","sets":["7"]},"author_link":["573653","573657","573659","573658","573655","573652","573656","573654"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-04","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"17","bibliographicPageStart":"13","bibliographicVolumeNumber":"43","bibliographic_titles":[{"bibliographic_title":"応用物理学会放射線分科会会誌「放射線」"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We introduce a new dose verification device for robotic radiosurgery using Al2O3:Cr ceramic 2D thermoluminescence dosimeter. It has high reproducibility, high spacial resolution, wide dynamic range and a low running cost. Because Al2O3:Cr is non - tissue equivalent, the influence of energy-dependency was one of the important considerations. However, the influence does not matter in the energy region from 100 keV to 6 MeV for robotic radiosurgery due to the ratio of the mass energy absorption coefficient having a constant with Al2O3:Cr and water. As a result, our new system using Al2O3:Cr ceramic 2D thermoluminescence dosimeter has a high usability for verification of not only geometric, but also dose.","subitem_description_type":"Abstract"}]},"item_10004_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0285-3604","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"眞正, 浄光"}],"nameIdentifiers":[{"nameIdentifier":"573652","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"栁澤, 伸"}],"nameIdentifiers":[{"nameIdentifier":"573653","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古場, 裕介"}],"nameIdentifiers":[{"nameIdentifier":"573654","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"井上, 光広"}],"nameIdentifiers":[{"nameIdentifier":"573655","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松本, 和樹"}],"nameIdentifiers":[{"nameIdentifier":"573656","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"牛場, 洋明"}],"nameIdentifiers":[{"nameIdentifier":"573657","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安藤, 隆之"}],"nameIdentifiers":[{"nameIdentifier":"573658","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古場 裕介","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"573659","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"TLDによる線量分布測定の高精度化 ~放射線治療の線量検証システムを目指して~","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"TLDによる線量分布測定の高精度化 ~放射線治療の線量検証システムを目指して~"}]},"item_type_id":"10004","owner":"1","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-05-16"},"publish_date":"2017-05-16","publish_status":"0","recid":"56063","relation_version_is_last":true,"title":["TLDによる線量分布測定の高精度化 ~放射線治療の線量検証システムを目指して~"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:42:13.794249+00:00"}