{"created":"2023-05-15T14:40:48.000470+00:00","id":55956,"links":{},"metadata":{"_buckets":{"deposit":"76da2db6-353b-4700-8bbe-8670ec3919a8"},"_deposit":{"created_by":1,"id":"55956","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"55956"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00055956","sets":["7"]},"author_link":["572583","572582"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-08","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"101","bibliographicPageStart":"100","bibliographicVolumeNumber":"2014","bibliographic_titles":[{"bibliographic_title":"National Institute of Radiological Sciences Annual Report 2014"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In Japan, postal dose audits have been performed on radiation\ntherapy units using radiophotoluminescent glass dosimeters\n(RGDs), since 2007 [1]. NIRS developed this auditing system and\nhas supported its technical aspects continuously. For instance,\nthe application of RGDs to a non-reference condition beam such\nas field size change or wedged field were studied by NIRS and\nsuccessfully introduced in the routine dose audit in 2010 [2] [3].\nThe IAEA / WHO have performed postal dose audits worldwide\nsince 1969 using thermoluminescent dosimeters (TLDs). Recently,\nThey have considered the replacement of TLDs by RGDs.\nRGDs are made in Japan and offer some superior features: RGDs\nare almost completely free from the fading effect and can be read\nrepeatedly. NIRS and IAEA have done an annual dosimetric intercomparison\nbetween RGDs and TLDs since 2008 (Fig.1). The outputs\nof both dosimeters agreed within ±1% (Table1). In 2013,\nIAEA installed a new RGD reader from Japan and started commissioning\nof the RGD system. IAEA asked NIRS to support this\nwork and I stayed at the IAEA Dosimetry Laboratory for 1 year\nfrom August 2013 as a consultant on the RGD system commissioning.","subitem_description_type":"Abstract"}]},"item_10004_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0439-5956","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"水野, 秀之"}],"nameIdentifiers":[{"nameIdentifier":"572582","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水野 秀之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"572583","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Technical consultation to the IAEA regarding dose audit system using radiophotoluminescent glass dosimeter developed by NIRS","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Technical consultation to the IAEA regarding dose audit system using radiophotoluminescent glass dosimeter developed by NIRS"}]},"item_type_id":"10004","owner":"1","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-08-18"},"publish_date":"2015-08-18","publish_status":"0","recid":"55956","relation_version_is_last":true,"title":["Technical consultation to the IAEA regarding dose audit system using radiophotoluminescent glass dosimeter developed by NIRS"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:43:27.236582+00:00"}