{"created":"2023-05-15T14:40:40.639340+00:00","id":55808,"links":{},"metadata":{"_buckets":{"deposit":"faa3fcf8-703e-48b0-9fba-bf0cea32e103"},"_deposit":{"created_by":1,"id":"55808","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"55808"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00055808","sets":["7"]},"author_link":["571069","571060","571063","571061","571062","571075","571073","571068","571071","571074","571067","571076","571066","571059","571070","571064","571072","571065"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-08","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"240","bibliographicPageStart":"239","bibliographicVolumeNumber":"NIRS-M-251","bibliographic_titles":[{"bibliographic_title":"放射線医学総合研究所重粒子線がん治療装置等共同利用研究報告書"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A portable radiation monitor named as \"CREPAS\" for dosimetry of high energy radiation has been developed. The signal waveforms are analyzed on site for the discrimination of different radiation components obtained with a phoswich-type scintillation probe. In the present study, the discrimination ability of the developed monitor was tested for accelerated carbon-ion beams and helium-ion beams at HIMAC. It was verified that the developed monitor can successfully detect helium ions and carbon ions separately. The extension of the dynamic range and the reduction of the angular dependence of the developed monitor are future problems.","subitem_description_type":"Abstract"}]},"item_10004_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"放医研"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"保田, 浩志"}],"nameIdentifiers":[{"nameIdentifier":"571059","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"矢島, 千秋"}],"nameIdentifiers":[{"nameIdentifier":"571060","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高田, 真志"}],"nameIdentifiers":[{"nameIdentifier":"571061","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"米内, 俊祐"}],"nameIdentifiers":[{"nameIdentifier":"571062","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松藤, 成弘"}],"nameIdentifiers":[{"nameIdentifier":"571063","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中村, 尚司"}],"nameIdentifiers":[{"nameIdentifier":"571064","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Anatoly, Rozenfeld"}],"nameIdentifiers":[{"nameIdentifier":"571065","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Livingstone, Jayde"}],"nameIdentifiers":[{"nameIdentifier":"571066","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Prokopovich, Anthony"}],"nameIdentifiers":[{"nameIdentifier":"571067","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"保田 浩志","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"571068","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"矢島 千秋","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"571069","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高田 真志","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"571070","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"米内 俊祐","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"571071","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松藤 成弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"571072","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中村 尚司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"571073","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Anatoly Rozenfeld","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"571074","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Livingstone Jayde","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"571075","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Prokopovich Anthony","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"571076","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"高エネルギー放射線場の線量評価に用いる携行型モニタの開発研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"高エネルギー放射線場の線量評価に用いる携行型モニタの開発研究"}]},"item_type_id":"10004","owner":"1","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-12-19"},"publish_date":"2012-12-19","publish_status":"0","recid":"55808","relation_version_is_last":true,"title":["高エネルギー放射線場の線量評価に用いる携行型モニタの開発研究"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:45:10.013613+00:00"}