{"created":"2023-05-15T14:40:36.519892+00:00","id":55715,"links":{},"metadata":{"_buckets":{"deposit":"ee45d5e8-54f7-48d1-b5e2-fdd67446d7ad"},"_deposit":{"created_by":1,"id":"55715","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"55715"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00055715","sets":["7"]},"author_link":["570098","570097","570106","570100","570102","570096","570107","570105","570099","570104","570101","570103"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010-12","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"NIRS-M-237","bibliographicPageEnd":"82","bibliographicPageStart":"79","bibliographicVolumeNumber":"2010","bibliographic_titles":[{"bibliographic_title":"放射線医学総合研究所技術報告書"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"PIXE分析は国内外の研究機関において、様々な研究分野で利用されており、近年、環境科学および医学生物学分野の応用研究が増加し、定量分析へのニーズが高まっている。PIXE分析で汎用されている測定試料の形状・形態として、乾燥試料を圧縮成型した錠剤型サンプル、液体試料の滴下乾燥サンプル、あるいは凍結組織切片等の薄切サンプルなどがあり、我々は定量分析に向けて各々の形状・形態に合わせた分析標準試料の確立を試みている。特に最近、水生環境生態試料のマイクロPIXE分析が数多くなされており、ミクロンレベルの空間分解能での局所量定量の要望が高い。そのため、数〜数百ppm程度の濃度範囲かつミクロンレベルでの均質性に優れた分析標準が望まれている。そこで、濃度調製の簡便な滴下乾燥分析標準に着目し、マイクロPIXE分析による性状評価を行ったので報告する。","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"磯, 浩之"}],"nameIdentifiers":[{"nameIdentifier":"570096","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"及川, 将一"}],"nameIdentifiers":[{"nameIdentifier":"570097","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川, 剛弘"}],"nameIdentifiers":[{"nameIdentifier":"570098","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"樋口, 有一"}],"nameIdentifiers":[{"nameIdentifier":"570099","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小西, 輝昭"}],"nameIdentifiers":[{"nameIdentifier":"570100","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"武田, 志乃"}],"nameIdentifiers":[{"nameIdentifier":"570101","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"磯 浩之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"570102","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"及川 将一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"570103","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川 剛弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"570104","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"樋口 有一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"570105","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小西 輝昭","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"570106","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"武田 志乃","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"570107","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"環境および生物試料のPIXE定量化に向けた分析標準試料の確立〜マイクロPIXEを用いた滴下標準の性状評価〜","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"環境および生物試料のPIXE定量化に向けた分析標準試料の確立〜マイクロPIXEを用いた滴下標準の性状評価〜"}]},"item_type_id":"10004","owner":"1","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-02-25"},"publish_date":"2011-02-25","publish_status":"0","recid":"55715","relation_version_is_last":true,"title":["環境および生物試料のPIXE定量化に向けた分析標準試料の確立〜マイクロPIXEを用いた滴下標準の性状評価〜"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:46:15.408363+00:00"}