{"created":"2023-05-15T14:40:34.717923+00:00","id":55674,"links":{},"metadata":{"_buckets":{"deposit":"f3daec6a-3595-4b38-b9a2-634e32e6c051"},"_deposit":{"created_by":1,"id":"55674","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"55674"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00055674","sets":["7"]},"author_link":["569682","569674","569678","569681","569683","569684","569676","569677","569679","569685","569680","569675"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-12","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"NIRS-M-227","bibliographicPageEnd":"13","bibliographicPageStart":"6","bibliographicVolumeNumber":"2009","bibliographic_titles":[{"bibliographic_title":"放射線医学総合研究所技術報告書"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"SPF(Specific Pathogen Free)動物生産・実験棟に設置されているガンマ線照射装置からの水吸収線量を2種類のコリメータについて再評価した。線量の絶対値は0.2mlファーマ型電離箱NE-2577(S/N=189)をKeithley 6517電位計に接続して測定した。また線量分布の測定は0.6mlファーマ電離箱c-110(S/N=525)にてタフウォータファントム中で行った。ビームプロファイルの測定には電離箱(c-110)を手動で移動する治具を製作し、5cm内の分布を取得した。また深部線量は深さ0.4mm〜2.6mmまで合計7点の測定を行い、BJRテーブル値2)とも比較検討した。\n絶対線量の測定結果は1%で線量テーブルの値と一致しており、いままでの値が正しいことを確認した。また他のコリメータに対しても決定した。深部線量分布については線源からの照射距離が短いため、組織中1mmで約1%異なるからターゲット位置の設定に注意が必要である。ビームプロファイルに平坦な領域はない","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"平岡, 武"}],"nameIdentifiers":[{"nameIdentifier":"569674","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三井, 大輔"}],"nameIdentifiers":[{"nameIdentifier":"569675","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酢屋, 徳啓"}],"nameIdentifiers":[{"nameIdentifier":"569676","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川, 剛弘"}],"nameIdentifiers":[{"nameIdentifier":"569677","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"濱野, 毅"}],"nameIdentifiers":[{"nameIdentifier":"569678","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"早尾, 辰雄"}],"nameIdentifiers":[{"nameIdentifier":"569679","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平岡 武","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569680","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三井 大輔","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569681","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酢屋 徳啓","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569682","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川 剛弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569683","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"濱野 毅","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569684","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"早尾 辰雄","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569685","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"SPF棟137Csガンマ線照射装置からの線量再評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"SPF棟137Csガンマ線照射装置からの線量再評価"}]},"item_type_id":"10004","owner":"1","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-01-14"},"publish_date":"2010-01-14","publish_status":"0","recid":"55674","relation_version_is_last":true,"title":["SPF棟137Csガンマ線照射装置からの線量再評価"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:46:44.596449+00:00"}