{"created":"2023-05-15T14:40:32.899064+00:00","id":55633,"links":{},"metadata":{"_buckets":{"deposit":"942ee786-cf51-42cd-a71e-6da85c5f1268"},"_deposit":{"created_by":1,"id":"55633","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"55633"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00055633","sets":["7"]},"author_link":["569258","569260","569256","569261","569267","569264","569254","569257","569265","569262","569266","569263","569255","569259"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-09","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"61","bibliographicPageStart":"56","bibliographicVolumeNumber":"2","bibliographic_titles":[{"bibliographic_title":"放射線医学総合研究所技術報告書"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"放医研のX線棟の標準線源室では、ガンマ線に対する検出器の校正試験だけではなく、低線量率での生物試実験が行われている。目的にあった線量率の場を決めるためにスタンド型ガンマ線照射装置の137Csを用いて標準線源室の各場所での線量率測定を行った。照射室内の位置、および、鉛板を吸収体として使用することで、137Cs線源で、約0.05〜100 mGy/hourの線量率での照射が可能である","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"海老澤, 悟"}],"nameIdentifiers":[{"nameIdentifier":"569254","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村, 尚"}],"nameIdentifiers":[{"nameIdentifier":"569255","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川, 剛弘"}],"nameIdentifiers":[{"nameIdentifier":"569256","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関, 等"}],"nameIdentifiers":[{"nameIdentifier":"569257","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酢屋, 徳啓"}],"nameIdentifiers":[{"nameIdentifier":"569258","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高野, 裕之"}],"nameIdentifiers":[{"nameIdentifier":"569259","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三井, 大輔"}],"nameIdentifiers":[{"nameIdentifier":"569260","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"海老澤 悟","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569261","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村 尚","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569262","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川 剛弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569263","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関 等","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569264","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酢屋 徳啓","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569265","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高野 裕之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569266","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三井 大輔","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569267","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"X線棟標準線源室における線量率の空間分布","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"X線棟標準線源室における線量率の空間分布"}]},"item_type_id":"10004","owner":"1","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-11-25"},"publish_date":"2008-11-25","publish_status":"0","recid":"55633","relation_version_is_last":true,"title":["X線棟標準線源室における線量率の空間分布"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:47:13.152081+00:00"}