{"created":"2023-05-15T14:40:32.811785+00:00","id":55631,"links":{},"metadata":{"_buckets":{"deposit":"c6631362-6156-4e52-836d-ad755104eed4"},"_deposit":{"created_by":1,"id":"55631","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"55631"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00055631","sets":["7"]},"author_link":["569242","569244","569245","569249","569243","569241","569240","569246","569248","569247"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"NIRS-M-215","bibliographicPageEnd":"74","bibliographicPageStart":"68","bibliographicVolumeNumber":"2008","bibliographic_titles":[{"bibliographic_title":"放射線医学総合研究所技術報告書"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"2008年3月上旬、放医研X線棟第3照射室に前X線照射装置PANTAK HF-320型の後継機としてX線発生装置TITAN-320型が設置された。装置更新に伴い、X線発生装置TITAN-320型の線量測定を実施した。 X線管焦点と照射台間距離(FSD)を変更することによって、3.51〜0.21Gy/minの範囲で照射が可能であり、高線量照射用回転テーブルを照射台に設置すると5.00Gy/min以上の(FSD235mm、照射野100mm)での照射が可能であることが確認された。","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"三井, 大輔"}],"nameIdentifiers":[{"nameIdentifier":"569240","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酢屋, 徳啓"}],"nameIdentifiers":[{"nameIdentifier":"569241","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川, 剛弘"}],"nameIdentifiers":[{"nameIdentifier":"569242","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"磯, 浩之"}],"nameIdentifiers":[{"nameIdentifier":"569243","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関, 等"}],"nameIdentifiers":[{"nameIdentifier":"569244","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三井 大輔","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569245","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酢屋 徳啓","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569246","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川 剛弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569247","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"磯 浩之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569248","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関 等","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"569249","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"X線発生装置TITAN-320型における線量測定結果","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"X線発生装置TITAN-320型における線量測定結果"}]},"item_type_id":"10004","owner":"1","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-10-24"},"publish_date":"2008-10-24","publish_status":"0","recid":"55631","relation_version_is_last":true,"title":["X線発生装置TITAN-320型における線量測定結果"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:47:14.674692+00:00"}