{"created":"2023-05-15T14:40:31.211884+00:00","id":55595,"links":{},"metadata":{"_buckets":{"deposit":"5cf792e0-cc6b-4c8b-ab29-ada65f3a8936"},"_deposit":{"created_by":1,"id":"55595","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"55595"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00055595","sets":["7"]},"author_link":["568824","568821","568830","568820","568825","568823","568822","568819","568829","568827","568828","568826"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"NIRS-M-205","bibliographicPageEnd":"42","bibliographicPageStart":"37","bibliographicVolumeNumber":"2007","bibliographic_titles":[{"bibliographic_title":"放射線医学総合研究所技術報告書"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"イオンビームを用いた元素分析法として、PIXE分析法がある。このPIXE 分析法は多元素を同時に分析することができることから、定性面の分析において数多く研究に用いられている。さらに定性だけでなく、近年では極微量元素の検出と、その定量化が強く望まれるようになった。そのため我々は静電加速器棟PIXE分析用加速器システムにおいて、定量化を可能とする技術開発を開始した。まず、定量化の第一段階として、最も一般的なPIXE分析ラインである真空中に試料を設置するコンベンショナルPIXEラインから改良を進めることにした。定量化において、試料に照射するイオンビーム照射量を正確に測定することが必須であることから、ビームチョッパー型リアルタイム電流モニタの開発を行った。","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"石川, 剛弘"}],"nameIdentifiers":[{"nameIdentifier":"568819","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"磯, 浩之"}],"nameIdentifiers":[{"nameIdentifier":"568820","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小西, 輝昭"}],"nameIdentifiers":[{"nameIdentifier":"568821","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村, 尚"}],"nameIdentifiers":[{"nameIdentifier":"568822","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"濱野, 毅"}],"nameIdentifiers":[{"nameIdentifier":"568823","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関, 等"}],"nameIdentifiers":[{"nameIdentifier":"568824","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川 剛弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"568825","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"磯 浩之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"568826","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小西 輝昭","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"568827","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村 尚","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"568828","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"濱野 毅","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"568829","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関 等","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"568830","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"PIXE分析法における定量法の確立(1) 〜ビーム電流リアルタイム測定システムの開発〜","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"PIXE分析法における定量法の確立(1) 〜ビーム電流リアルタイム測定システムの開発〜"}]},"item_type_id":"10004","owner":"1","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-01-08"},"publish_date":"2008-01-08","publish_status":"0","recid":"55595","relation_version_is_last":true,"title":["PIXE分析法における定量法の確立(1) 〜ビーム電流リアルタイム測定システムの開発〜"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:47:39.238447+00:00"}