{"created":"2023-05-15T14:40:31.077795+00:00","id":55592,"links":{},"metadata":{"_buckets":{"deposit":"2b478242-71f4-4be1-8d91-4943d13ffa68"},"_deposit":{"created_by":1,"id":"55592","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"55592"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00055592","sets":["7"]},"author_link":["568779","568780","568786","568788","568787","568782","568783","568784","568785","568789","568781","568778","568790"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"NIRS-M-205","bibliographicPageEnd":"7","bibliographicPageStart":"1","bibliographicVolumeNumber":"2007","bibliographic_titles":[{"bibliographic_title":"放射線医学総合研究所技術報告書"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In order to perform Linear Energy Transfer (LET) measurements for 290 MeV/u carbon beam, used for radiotherapy at the National Institute of Radiological Sciences, we used passive CR-39 Plastic Nuclear Track Detectors. The response curves for two kinds of CR-39s (TD-1 and TNF-1 detectors) were obtained using several species of ions and energies. Detection efficiency and LET resolution of TD-1 for therapeutic carbon ion were measured to be 100% and ~ 1 keV/m (FWHM), respectively. Sensitivity degradation in water was confirmed for TD-1 detector.","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"安田, 仲宏"}],"nameIdentifiers":[{"nameIdentifier":"568778","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"蔵野, 美恵子"}],"nameIdentifiers":[{"nameIdentifier":"568779","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宗, 大路"}],"nameIdentifiers":[{"nameIdentifier":"568780","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"川嶋, 元"}],"nameIdentifiers":[{"nameIdentifier":"568781","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小平, 聡"}],"nameIdentifiers":[{"nameIdentifier":"568782","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"落合, 佳子"}],"nameIdentifiers":[{"nameIdentifier":"568783","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"シーバー, レンビット"}],"nameIdentifiers":[{"nameIdentifier":"568784","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安田 仲宏","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"568785","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"蔵野 美恵子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"568786","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宗 大路","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"568787","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"川嶋 元","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"568788","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小平 聡","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"568789","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"落合 佳子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"568790","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Performance test of CR-39 plastic nuclear track detectors for therapeutic carbon beam dosimetry","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Performance test of CR-39 plastic nuclear track detectors for therapeutic carbon beam dosimetry"}]},"item_type_id":"10004","owner":"1","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-01-08"},"publish_date":"2008-01-08","publish_status":"0","recid":"55592","relation_version_is_last":true,"title":["Performance test of CR-39 plastic nuclear track detectors for therapeutic carbon beam dosimetry"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:47:41.996515+00:00"}