{"created":"2023-05-15T14:40:19.509632+00:00","id":55330,"links":{},"metadata":{"_buckets":{"deposit":"5f983b49-f384-4034-8d89-2128dd5f8106"},"_deposit":{"created_by":1,"id":"55330","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"55330"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00055330","sets":["7"]},"author_link":["565755","565756"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2004-08","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"267","bibliographicPageStart":"257","bibliographicVolumeNumber":"47","bibliographic_titles":[{"bibliographic_title":"放射線科学"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"放医研のPIXE分析加速器システム(PASTA)は、稼働開始から6年目に入りました。その間の利用ユーザー数は、延べ2400件(平均470件/年)、マシンタイムは延べ7200時間(平均1450時/年)と年間を通じ、ほぼフル稼働してきました。その間、できるだけ多くのマシンタイムを提供することを第一の使命としながらも、分析精度向上のために装置改良等の技術開発を続けています。それだけではなく加速器の利用拡大のために、2003年3月には、マイクロビーム細胞照射装置(SPICE)を導入し、2003年11月に最初の細胞照射を行うなど、新たな装置の導入も進めてきました。さらに2004年4月には、共用施設として、理事長から指定され、当面は共同研究に限定されていますが、近い将来、本当の意味での共用施設として所内外の利用者が利用できるように、運用方針についても検討を重ねています。システムの概要については、放射線科学Vol44(2001,4月)及びVol.45(2002,4月)で報告しましたが、新しく利用を希望する方々の便宜を図るため、PASTA 及びSPICEは、どのような施設であるかを最新の状況をふまえ、改めて紹介します。","subitem_description_type":"Abstract"}]},"item_10004_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0441-2540","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"今関, 等"}],"nameIdentifiers":[{"nameIdentifier":"565755","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関 等","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"565756","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"PIXE分析用加速器システム(PASTA)とマイクロビーム細胞照射装置(SPICE)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"PIXE分析用加速器システム(PASTA)とマイクロビーム細胞照射装置(SPICE)"}]},"item_type_id":"10004","owner":"1","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2004-12-10"},"publish_date":"2004-12-10","publish_status":"0","recid":"55330","relation_version_is_last":true,"title":["PIXE分析用加速器システム(PASTA)とマイクロビーム細胞照射装置(SPICE)"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:50:46.995958+00:00"}