{"created":"2023-05-15T14:40:18.467888+00:00","id":55307,"links":{},"metadata":{"_buckets":{"deposit":"720bb3c8-a636-4982-b377-a594b81e65c0"},"_deposit":{"created_by":1,"id":"55307","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"55307"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00055307","sets":["7"]},"author_link":["565586","565587","565579","565583","565584","565585","565581","565578","565582","565580"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003-09","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"360","bibliographicPageStart":"356","bibliographic_titles":[{"bibliographic_title":"厚生労働省がん研究助成金による研究報告集"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"肺癌、大腸癌、悪性リンパ腫では、ブドウ糖代謝を指標としたFDG-PET検査の優れた診断能が認められたのに対し、原発不明癌、特に頚部から発症した扁平上皮癌ではFDG-PETを施行しても、原発巣の発見率は低かった。保険収載されていない食道癌、婦人科腫瘍でもFDG-PETの有用性が確かめられた。頭頚部の根治的放射線治療において、FDG-PETとCTやMRIなど形態学的画像の重ね合わせ画像と強度変調放射線治療(IMRT)等の精密な治療計画法を併用することで、的確な病変の範囲を決定し、放射線治療計画作成に寄与できた。抗がん剤による治療効果判定へのFDG-PET利用の動物実験および新しい腫瘍診断用のPET製剤の開発に取り組んだ。11C標識メチオニンはFDGに比べて骨盤への生理的な分布が少なく卵巣腫瘍で有用だった。PETカメラなど機器の開発も行われており呼吸同期法、CT/PET一体型装置などによる診断精度向上が期待される。","subitem_description_type":"Abstract"}]},"item_10004_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1346-9169","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"遠藤, 啓吾"}],"nameIdentifiers":[{"nameIdentifier":"565578","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"玉木, 長良"}],"nameIdentifiers":[{"nameIdentifier":"565579","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福田, 寛"}],"nameIdentifiers":[{"nameIdentifier":"565580","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉川, 京燦"}],"nameIdentifiers":[{"nameIdentifier":"565581","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐治, 英郎"}],"nameIdentifiers":[{"nameIdentifier":"565582","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"その他"}],"nameIdentifiers":[{"nameIdentifier":"565583","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"遠藤 啓吾","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"565584","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福田 寛","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"565585","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉川 京燦","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"565586","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐治 英郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"565587","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ポジトロンCTのがん診断への応用及び診断精度向上に関する研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ポジトロンCTのがん診断への応用及び診断精度向上に関する研究"}]},"item_type_id":"10004","owner":"1","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2004-08-26"},"publish_date":"2004-08-26","publish_status":"0","recid":"55307","relation_version_is_last":true,"title":["ポジトロンCTのがん診断への応用及び診断精度向上に関する研究"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:51:03.041034+00:00"}