{"created":"2023-05-15T14:40:15.021337+00:00","id":55229,"links":{},"metadata":{"_buckets":{"deposit":"dc68eb91-a910-4126-9c90-7ac70bc0ff95"},"_deposit":{"created_by":1,"id":"55229","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"55229"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00055229","sets":["7"]},"author_link":["564884","564882","564886","564880","564883","564885","564881","564887"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003-04","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"267","bibliographicPageStart":"266","bibliographic_titles":[{"bibliographic_title":"Annual Report of the Research Project with Heavy Ions at NIRS-HIMAC"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The response of various types of thermoluminescent materials as 6LiF:Mg,T (TLD 600), 7LiF:Mg (TLD 700), Ti and CaF2:Tm to heavy charged particles is investigated. The data gathered during the irradiation campaign in the year 2002 is a base for the further evaluation of the different LET dependencies of the high temperature emission peaks of LiF thermoluminescent materials. This is also used to evaluate data measured during exposure of thermoluminescent dosemeters onboard the International Space Station ISS. Additional Cr-39 track etch detectors were used for beam monitoring and for dose verification.","subitem_description_type":"Abstract"}]},"item_10004_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"放医研"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Berger, Thomas"}],"nameIdentifiers":[{"nameIdentifier":"564880","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hajek, Michael"}],"nameIdentifiers":[{"nameIdentifier":"564881","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Summerer, Leopold"}],"nameIdentifiers":[{"nameIdentifier":"564882","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Uchihori, Yukio"}],"nameIdentifiers":[{"nameIdentifier":"564883","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kitamura, Hisashi"}],"nameIdentifiers":[{"nameIdentifier":"564884","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"564885","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内堀 幸夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"564886","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村 尚","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"564887","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"LET calibration of the TL response of CaF2:Tm - further investigations (13P-126)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"LET calibration of the TL response of CaF2:Tm - further investigations (13P-126)"}]},"item_type_id":"10004","owner":"1","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2004-01-23"},"publish_date":"2004-01-23","publish_status":"0","recid":"55229","relation_version_is_last":true,"title":["LET calibration of the TL response of CaF2:Tm - further investigations (13P-126)"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:51:56.997252+00:00"}