{"created":"2023-05-15T14:40:11.853183+00:00","id":55157,"links":{},"metadata":{"_buckets":{"deposit":"4f11f14c-268f-4bc7-a6f5-3ff2a3aba023"},"_deposit":{"created_by":1,"id":"55157","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"55157"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00055157","sets":["7"]},"author_link":["564318","564313","564320","564312","564314","564317","564315","564319","564316"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"11/16","bibliographicPageEnd":"28","bibliographicPageStart":"23","bibliographicVolumeNumber":"02","bibliographic_titles":[{"bibliographic_title":"電気学会研究会資料 NE, 原子力研究会"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"ガンマ線源の分布測定装置としてのコンプトンカメラは、効率のよい分布測定装置として1970年代に提案され、近年まで比較的緩やかな発展が続けられたが、半導体放射線検出器の技術発展、及び、分子生物学分野での高分解能機能断層画像の要求を受け、ここ数年コンプトンカメラ関係の研究発表が多くなっている。本論文では、コンプトンカメラの原理と補正点、分布像再構成法、検出器構成例について解説する。","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"平澤, 雅彦"}],"nameIdentifiers":[{"nameIdentifier":"564312","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"富谷, 武浩"}],"nameIdentifiers":[{"nameIdentifier":"564313","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"柴田, 貞夫"}],"nameIdentifiers":[{"nameIdentifier":"564314","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"榎本, 秀一"}],"nameIdentifiers":[{"nameIdentifier":"564315","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"矢野, 安重"}],"nameIdentifiers":[{"nameIdentifier":"564316","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平澤 雅彦","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"564317","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"富谷 武浩","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"564318","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"柴田 貞夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"564319","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"矢野 安重","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"564320","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"コンプトンカメラによるガンマ線源分布測定技術とその動向","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"コンプトンカメラによるガンマ線源分布測定技術とその動向"}]},"item_type_id":"10004","owner":"1","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-10-20"},"publish_date":"2003-10-20","publish_status":"0","recid":"55157","relation_version_is_last":true,"title":["コンプトンカメラによるガンマ線源分布測定技術とその動向"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:52:45.826911+00:00"}