{"created":"2023-05-15T14:40:06.743064+00:00","id":55042,"links":{},"metadata":{"_buckets":{"deposit":"89a6cce4-1a51-4e62-8cd8-ccc33bb07d2c"},"_deposit":{"created_by":1,"id":"55042","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"55042"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00055042","sets":["7"]},"author_link":["562872","562873"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-03","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"000","bibliographic_titles":[{"bibliographic_title":"The Report of the Criticality Accident in a Uranium Conversion Test Plant in Tokai-Mura"}]}]},"item_10004_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"National Institute of Radiological Sciences"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ishigure, Nobuhito"}],"nameIdentifiers":[{"nameIdentifier":"562872","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石榑 信人","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"562873","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"(1)\"Estimation of Doses Based on 24Na Measured in the Blood\"(p.22-p.26), (2)\"Precise Analysis of Dose Distribution\"(p.32-p.39)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"(1)\"Estimation of Doses Based on 24Na Measured in the Blood\"(p.22-p.26), (2)\"Precise Analysis of Dose Distribution\"(p.32-p.39)"}]},"item_type_id":"10004","owner":"1","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-07-23"},"publish_date":"2003-07-23","publish_status":"0","recid":"55042","relation_version_is_last":true,"title":["(1)\"Estimation of Doses Based on 24Na Measured in the Blood\"(p.22-p.26), (2)\"Precise Analysis of Dose Distribution\"(p.32-p.39)"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:54:04.957945+00:00"}