{"created":"2023-05-15T14:40:02.595439+00:00","id":54950,"links":{},"metadata":{"_buckets":{"deposit":"86e43c10-b7b2-4cb0-b8b8-a61ed9b6ef3e"},"_deposit":{"created_by":1,"id":"54950","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"54950"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00054950","sets":["2"]},"author_link":["561924","561921","561922","561923"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-01","bibliographicIssueDateType":"Issued"},"bibliographic_titles":[{"bibliographic_title":"第15回日本加速器学会年会論文集"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Controlling carrier-envelope phase (CEP) of few-cycle laser pulses is necessary for applications such as quantum\ncontrol of molecular processes, optical frequency combs and high-harmonic generation (HHG). In this paper, a method\nof CEP stabilization in a FEL oscillator is presented. The method is based on a continuous injection of CEP-stable seed\nlaser pulses into the FEL oscillator. We discuss accuracy of the CEP stabilization under the influence of jitters in the seed\nlaser and the electron beam. Application of the CEP-stable FEL pulses to the generation of attosecond X-ray pulses via\nHHG is also introduced.","subitem_description_type":"Abstract"}]},"item_10003_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://www.pasj.jp/web_publish/pasj2018/proceedings/PDF/FROL/FROL01.pdf"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.pasj.jp/web_publish/pasj2018/proceedings/PDF/FROL/FROL01.pdf","subitem_relation_type_select":"URI"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"羽島, 良一"}],"nameIdentifiers":[{"nameIdentifier":"561921","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"永井, 良治"}],"nameIdentifiers":[{"nameIdentifier":"561922","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"羽島 良一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"561923","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"永井 良治","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"561924","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"高次高調波によるアト秒X線発生のための中赤外自由電子レーザの位相安定化方法の提案","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"高次高調波によるアト秒X線発生のための中赤外自由電子レーザの位相安定化方法の提案"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-01-10"},"publish_date":"2019-01-10","publish_status":"0","recid":"54950","relation_version_is_last":true,"title":["高次高調波によるアト秒X線発生のための中赤外自由電子レーザの位相安定化方法の提案"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:55:03.642682+00:00"}