{"created":"2023-05-15T14:39:55.816715+00:00","id":54797,"links":{},"metadata":{"_buckets":{"deposit":"f0bfed3b-fe70-489b-91bb-8c59aef793fa"},"_deposit":{"created_by":1,"id":"54797","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"54797"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00054797","sets":["2"]},"author_link":["560191","560190","560189","560187","560192","560194","560188","560193"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-10","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"185","bibliographicPageStart":"180","bibliographicVolumeNumber":"2016-8","bibliographic_titles":[{"bibliographic_title":"Proceedings of the 17th Workshop on Environmental Radioactivity"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In this study, a detail evaluation is made of the new sector-field ICP-MS (Element XR) on its analytical potential for ultra-trace determination of 241Am. In order to enhance the sensitivity for 241Am analysis, a high efficiency sample introduction system (Aridus II) was combined with the Element XR. Analytical parameters, such as the RF power of SF-ICP-MS, flow rates of Ar sweep gas and N2 gas of the Aridus system were carefully optimized. A detection limit at attogram (10-18 g) level was obtained, which is comparable or even better than that of AMS, indicating a significant advance of ICP-MS for ultra-trace 241Am measurements. ","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Zheng, Jian"}],"nameIdentifiers":[{"nameIdentifier":"560187","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Wang, Zhongtang"}],"nameIdentifiers":[{"nameIdentifier":"560188","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tagami, Keiko"}],"nameIdentifiers":[{"nameIdentifier":"560189","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Uchida, Shigeo"}],"nameIdentifiers":[{"nameIdentifier":"560190","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鄭 建","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"560191","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"王 鍾堂","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"560192","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田上 恵子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"560193","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内田 滋夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"560194","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Ultra-trace determination of Am-241 by SF-ICP-MS combined with a high efficiency sample introduction system","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Ultra-trace determination of Am-241 by SF-ICP-MS combined with a high efficiency sample introduction system"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-07-13"},"publish_date":"2017-07-13","publish_status":"0","recid":"54797","relation_version_is_last":true,"title":["Ultra-trace determination of Am-241 by SF-ICP-MS combined with a high efficiency sample introduction system"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:56:40.306905+00:00"}