{"created":"2023-05-15T14:39:55.290819+00:00","id":54785,"links":{},"metadata":{"_buckets":{"deposit":"9dcba179-baa5-4800-b07e-033c93a6af7a"},"_deposit":{"created_by":1,"id":"54785","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"54785"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00054785","sets":["2"]},"author_link":["560084","560082","560083","560078","560080","560085","560081","560077","560079"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-11","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"238","bibliographicPageStart":"233","bibliographicVolumeNumber":"1","bibliographic_titles":[{"bibliographic_title":"Proceedings of the 17th Workshop on Environmental Radioactivity"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Radon concentrations are measured using a PICO-RAD activated charcoal collector, which is usually fitted with a conventional liquid scintillation counter (LSC) and its dedicated software. In this study, PICO-RAD collectors were exposed to a known radon concentration in a chamber at the National Institute of Radiological Science (NIRS), and evaluated by the LSC (without the dedicated software) using an integral counting method. In addition, a conversion equation was determined between counting rate and radon concentration. We showed that radon concentration could be measured by the PICO-RAD collector using a conventional and simplified LSC instrument. It is required that the minimum detectable Rn concentration should be kept at 10% of the recommended reference level. Simplified LSC produced an approximately six-fold higher background level than its conventional counterpart, however it exhibited a minimum detectable radon concentration as low as 30 Bq m−3.","subitem_description_type":"Abstract"}]},"item_10003_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"KEK, Tsukuba"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Arai, Y."}],"nameIdentifiers":[{"nameIdentifier":"560077","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Wakabayashi, A."}],"nameIdentifiers":[{"nameIdentifier":"560078","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yasuoka, Y."}],"nameIdentifiers":[{"nameIdentifier":"560079","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Iwaoka, K."}],"nameIdentifiers":[{"nameIdentifier":"560080","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tokonami, S."}],"nameIdentifiers":[{"nameIdentifier":"560081","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"ミロソラフ, ヤニック"}],"nameIdentifiers":[{"nameIdentifier":"560082","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fukuhori, N."}],"nameIdentifiers":[{"nameIdentifier":"560083","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mukai, T."}],"nameIdentifiers":[{"nameIdentifier":"560084","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"ミロソラフ ヤニック","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"560085","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Radon Testing in Air using a PICO-RAD Collector Measured with a Simplified Liquid Scintillation Counter ","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Radon Testing in Air using a PICO-RAD Collector Measured with a Simplified Liquid Scintillation Counter "}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-07-12"},"publish_date":"2017-07-12","publish_status":"0","recid":"54785","relation_version_is_last":true,"title":["Radon Testing in Air using a PICO-RAD Collector Measured with a Simplified Liquid Scintillation Counter "],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:56:48.854601+00:00"}