@inproceedings{oai:repo.qst.go.jp:00054693, author = {岩田, 佳之 and 藤澤, 高志 and 北條, 悟 and 宮原, 信幸 and 村上, 健 and 村松, 正幸 and 小川, 博嗣 and 坂本, 幸雄 and 山田, 聰 and 山本, 和男 and 藤本, 哲也 and 竹内, 猛 and 密本, 俊典 and 筒井, 裕士 and 上田, 隆正 and 渡辺, 崇 and 岩田 佳之 and 藤澤 高志 and 北條 悟 and 宮原 信幸 and 村上 健 and 村松 正幸 and 小川 博嗣 and 坂本 幸雄 and 山田 聰 and 山本 和男 and 竹内 猛 and 上田 隆正 and 渡辺 崇}, book = {Proceedings of Linear Accelerator Conference (LINAC06)}, month = {Aug}, note = {A compact injector, designed for a medical accelerator complex, was constructed. It consists of an Electron-Cyclotron-Resonance Ion-Source (ECRIS) and two linacs, which are a Radio-Frequency-Quadrupole (RFQ) linac and an Alternating-Phase-Focused Interdigital H-mode Drift-Tube-Linac (APF IH-DTL) having the same operating frequency of 200 MHz. The compact injector can accelerate carbon ions of 12C4+ up to 4.0 MeV/u. Use of the APF IH-DTL enabled us to design the compact injector; the total length of the two linacs is approximately 6m. After installation of the compact injector, beam acceleration tests were performed. We have succeeded to accelerate carbon ions with satisfactory performance. An overview of the compact injector as well as results of the beam acceleration tests is described.}, title = {PERFORMANCE OF ALTERNATING-PHASE-FOCUSED IH-DTL}, year = {2006} }