{"created":"2023-05-15T14:39:45.887601+00:00","id":54606,"links":{},"metadata":{"_buckets":{"deposit":"b619f97c-59c1-4ace-9c3a-79ed3d1181de"},"_deposit":{"created_by":1,"id":"54606","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"54606"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00054606","sets":["2"]},"author_link":["833993","833995","833991","833994","833996","833997","833990","833992"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"NIRS-M-278","bibliographicPageEnd":"78","bibliographicPageStart":"74","bibliographicVolumeNumber":"9","bibliographic_titles":[{"bibliographic_title":"第9回技術と安全の報告会 報告集"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"分子神経イメージング研究プログラムでは摘出したマウス脳を直接、あるいはPFAで固定後にクライオスタット(凍結切片作製装置)にて凍結切片を作製しているが、しばしば組織内の空隙や核の脱落等が見られ、本来の組織構造を保持していない粗悪な切片ができることがある。そこで今回、組織構造を保持した良質な組織切片を得るために、標本作りの各工程(固定時間の長短、スクロース置換濃度、凍結温度等)の条件検討を行ったので報告する。","subitem_description_type":"Abstract"}]},"item_10003_relation_10":{"attribute_name":"ISBN","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"978-4-938987-97-8","subitem_relation_type_select":"ISBN"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"南久松, 丈晴"}],"nameIdentifiers":[{"nameIdentifier":"833990","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小野, 麻衣子"}],"nameIdentifiers":[{"nameIdentifier":"833991","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"須原, 哲也"}],"nameIdentifiers":[{"nameIdentifier":"833992","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"樋口, 真人"}],"nameIdentifiers":[{"nameIdentifier":"833993","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Minamihisamatsu, Takeharu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"833994","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ono, Maiko","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"833995","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Suhara, Tetsuya","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"833996","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Higuchi, Makoto","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"833997","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"粗悪な病理組織切片の原因とその対策","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"粗悪な病理組織切片の原因とその対策"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-12-01"},"publish_date":"2015-12-01","publish_status":"0","recid":"54606","relation_version_is_last":true,"title":["粗悪な病理組織切片の原因とその対策"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:56:31.119752+00:00"}