{"created":"2023-05-15T14:39:44.313618+00:00","id":54574,"links":{},"metadata":{"_buckets":{"deposit":"2859af8c-a227-4886-a71b-009b6268f39e"},"_deposit":{"created_by":1,"id":"54574","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"54574"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00054574","sets":["2"]},"author_link":["557509","557520","557512","557514","557517","557518","557513","557506","557515","557510","557516","557508","557519","557521","557511","557507"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-07","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"114","bibliographicPageStart":"110","bibliographic_titles":[{"bibliographic_title":"第9回技術と安全の報告会 報告集"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"病院内でPET薬剤を製造する際、「無菌性の確保」が大きな課題となる。その達成のためには、(1)更衣等の手間やコストの増大、無菌操作技術の習得に起因する無菌性を確保することの困難さ、(2)(1)の結果として生じる作業効率及び精度の低下、等の克服が必要となる。標準化推進・品質保証室及び分子認識研究PGは、この度この2つの課題を同時に克服し、より高次元の無菌性確保を可能とする装置(PET薬剤製剤化用無菌アイソレータ)を協力企業と共に開発した。この装置は給排気HEPAユニット、陽圧設定高気密装置、過酸化水素による除染装置から成り、微生物から庫内を完全に分離した環境下で作業者はグローブを通して作業を行う。特に最終製剤化の工程は、遮蔽体に覆われた自動分注器により、被曝することなく行われる。この装置により、放医研のみならず世界のPET薬剤製造施設で、医薬品レベルの高い無菌性保証が可能になると期待される。","subitem_description_type":"Abstract"}]},"item_10003_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"国立研究開発法人 放射線医学総合研究所"}]},"item_10003_relation_10":{"attribute_name":"ISBN","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"978-4-938987-98-5","subitem_relation_type_select":"ISBN"}}]},"item_10003_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://www.nirs.go.jp/publication/irregular/04.shtml"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.nirs.go.jp/publication/irregular/04.shtml","subitem_relation_type_select":"URI"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"脇, 厚生"}],"nameIdentifiers":[{"nameIdentifier":"557506","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金子, いづみ"}],"nameIdentifiers":[{"nameIdentifier":"557507","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岩隈, 佳寿子"}],"nameIdentifiers":[{"nameIdentifier":"557508","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河村, 和紀"}],"nameIdentifiers":[{"nameIdentifier":"557509","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木, 寿"}],"nameIdentifiers":[{"nameIdentifier":"557510","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"橋本, 裕輝"}],"nameIdentifiers":[{"nameIdentifier":"557511","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"張, 明栄"}],"nameIdentifiers":[{"nameIdentifier":"557512","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤林, 康久"}],"nameIdentifiers":[{"nameIdentifier":"557513","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"脇 厚生","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"557514","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金子 いづみ","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"557515","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岩隈 佳寿子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"557516","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河村 和紀","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"557517","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木 寿","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"557518","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"橋本 裕輝","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"557519","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"張 明栄","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"557520","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤林 康久","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"557521","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"世界初PET薬剤製剤化用無菌アイソレータの開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"世界初PET薬剤製剤化用無菌アイソレータの開発"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-07-23"},"publish_date":"2015-07-23","publish_status":"0","recid":"54574","relation_version_is_last":true,"title":["世界初PET薬剤製剤化用無菌アイソレータの開発"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:59:17.586593+00:00"}