{"created":"2023-05-15T14:39:41.843650+00:00","id":54518,"links":{},"metadata":{"_buckets":{"deposit":"66e5ea42-4d82-43c8-8545-8c701141a19d"},"_deposit":{"created_by":1,"id":"54518","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"54518"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00054518","sets":["2"]},"author_link":["556811","556816","556815","556819","556818","556820","556812","556813","556814","556817"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014-11","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"921","bibliographicPageStart":"918","bibliographicVolumeNumber":"34","bibliographic_titles":[{"bibliographic_title":"医療情報学 34(Suppl.)"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"【はじめに】腫瘍再発のため近接部位に複数回放射線治療を行う場合、放射線障害のリスク低減の為、過去の線量分布となるべく重複しない治療計画を行う必要がある。本研究では2回目以降の新たな治療計画を行う際に過去の線量分布の正確な位置を把握できる方法を開発することを目的とする。これまで、実際の症例データを基に放射線治療情報への適用の検討を行った。【方法】複数回治療を行った患者の画像および精度評価検討のために作成したファントム画像を対象として、次の手順で画像の変形処理を行った。Step1)変形する対象の線量分布情報はDICOM-RTのPLAN/DOSE情報からCT画像と同様の画像データに変換する。Step2)3次元の自由形状変形法(Free Form Deformation; FFD) を用いて、変形する対象のCT画像を基準とするCT画像に対して非線形な位置合わせを行う。Step3)step2で得られた変形パラメタを用いて、step1で作成した線量分布画像を変形させ、基準とするCT画像に位置合わせする。Step4)位置合わせした線量分布画像を、DICOM-RTのPLAN/DOSE情報に再変換を行う。Step5)変形したDICOM-RTのPLAN/DOSE情報と基準とするCT画像を重ね合わせて表示する。非線形位置合せには、The Insight Toolkit(ITK)の非線形位置合せライブラリを採用した。【結果/考察】演算時間は、30分/症例程度であった。位置合わせ後に生成された線量分布画像について、医師らによる確認を行った結果、不自然な変形は存在しなかった。このことはDICOM-RT画像に対しても本手法が妥当な変形を行っていることを裏付ける。【今後の計画】今後は炭素線等の急峻な分布を形成する治療計画データについて検証を進めていく予定である。","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"向井, まさみ"}],"nameIdentifiers":[{"nameIdentifier":"556811","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"向井まさみ"}],"nameIdentifiers":[{"nameIdentifier":"556812","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"横岡, 由姫"}],"nameIdentifiers":[{"nameIdentifier":"556813","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"奥田, 保男"}],"nameIdentifiers":[{"nameIdentifier":"556814","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安藤, 裕"}],"nameIdentifiers":[{"nameIdentifier":"556815","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"556816","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"向井 まさみ","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"556817","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"横岡 由姫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"556818","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"奥田 保男","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"556819","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安藤 裕","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"556820","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"放射線治療計画支援のための3次元非線形位置合わせ手法のDICOM-RT画像への適用の評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"放射線治療計画支援のための3次元非線形位置合わせ手法のDICOM-RT画像への適用の評価"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-12-04"},"publish_date":"2014-12-04","publish_status":"0","recid":"54518","relation_version_is_last":true,"title":["放射線治療計画支援のための3次元非線形位置合わせ手法のDICOM-RT画像への適用の評価"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:59:56.739745+00:00"}