{"created":"2023-05-15T14:39:38.848357+00:00","id":54451,"links":{},"metadata":{"_buckets":{"deposit":"3678a6cc-d8c4-4438-b5c9-05156ea397ac"},"_deposit":{"created_by":1,"id":"54451","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"54451"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00054451","sets":["2"]},"author_link":["556082","556083","556077","556084","556076","556085","556075","556086","556078","556081","556080","556079"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"Sup","bibliographicPageStart":"338","bibliographicVolumeNumber":"31","bibliographic_titles":[{"bibliographic_title":"Abstruct of 6th Japan-Korea Joint Meeting on Medical Physics and 11th Asica-Oceania Congress of Medical Physics"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In Japan for therapu-level dosimeter usere's dosimeters are calibrated in Therapy Level dosimeter Calibration Center , Association ffor Nuclear Technology in Medicine in terms of exposure dose for Co60 gamma-ray using ANTM secondary standard dosimeter. ANTM acts as a secondary standard dosimeter laboratry in Japan and has calibrated dosimeters all over Japan since 2004. According to the calibration frequency of facilities over 60% were calibrated within 1.15%. The exposure calibration factor differences of user dosimeter for 6 years by ANTM, the variation of these distributions was almost within our relative expanded uncertainty, 1.5%.","subitem_description_type":"Abstract"}]},"item_10003_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"J"}]},"item_10003_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1345-5362","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"矢島, 佳央理"}],"nameIdentifiers":[{"nameIdentifier":"556075","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takase, Nobuhiro"}],"nameIdentifiers":[{"nameIdentifier":"556076","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Uesaka, Saki"}],"nameIdentifiers":[{"nameIdentifier":"556077","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Katayose, Tetsuro"}],"nameIdentifiers":[{"nameIdentifier":"556078","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamashita, Wataru"}],"nameIdentifiers":[{"nameIdentifier":"556079","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Narita, Katsuhisa"}],"nameIdentifiers":[{"nameIdentifier":"556080","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanai, Tatsuaki"}],"nameIdentifiers":[{"nameIdentifier":"556081","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福村, 明史"}],"nameIdentifiers":[{"nameIdentifier":"556082","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水野, 秀之"}],"nameIdentifiers":[{"nameIdentifier":"556083","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"矢島 佳央理","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"556084","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福村 明史","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"556085","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水野 秀之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"556086","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Calibration of Therapy-level dosimeter in Japan by ANTM","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Calibration of Therapy-level dosimeter in Japan by ANTM"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-02-02"},"publish_date":"2014-02-02","publish_status":"0","recid":"54451","relation_version_is_last":true,"title":["Calibration of Therapy-level dosimeter in Japan by ANTM"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:00:48.790677+00:00"}