{"created":"2023-05-15T14:39:38.221735+00:00","id":54437,"links":{},"metadata":{"_buckets":{"deposit":"a81c1951-7535-4f22-8c65-a19eb51de687"},"_deposit":{"created_by":1,"id":"54437","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"54437"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00054437","sets":["2"]},"author_link":["555978","555976","555977","555975","555980","555979"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013-12","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"364","bibliographicPageStart":"359","bibliographicVolumeNumber":"13","bibliographic_titles":[{"bibliographic_title":"Proceedings of the 14th Workshop on Environmental Radiactivity"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Radioactive Cs isotopes are high yield fission products up to 6.535% and 6.236% for 135Cs and 137Cs, respectively, from thermal neutron fission of 235U. They can be released into the environment in nuclear events like the detonation of a nuclear weapon or nuclear reactor accident. In the fission chains for 135Cs and 137Cs, a shielding of 135Cs occurs due to neutron capture of its precursor, 135Xe, to form 136Xe, whereas production of 137Cs is unaffected. This process causes a high degree of variance of 135Cs/137Cs isotope ratio with source. Thus, the ratio of 135Cs/137Cs will be characteristic of the reactor operation and shutdown conditions. In addition, the isotope ratio of 135Cs/137Cs is very important in many aspects in radioecological studies, including source identification of radioactive contamination, dispersion modeling of fission products in the environment after a nuclear accident, long-term estimation of environmental behavior of Cs, and development of accurate sediment geochronology.","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"鄭, 建"}],"nameIdentifiers":[{"nameIdentifier":"555975","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田上, 恵子"}],"nameIdentifiers":[{"nameIdentifier":"555976","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内田, 滋夫"}],"nameIdentifiers":[{"nameIdentifier":"555977","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鄭 建","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"555978","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田上 恵子","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"555979","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内田 滋夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"555980","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Exploring analytical potential of ICP-MS for the determination of radioactive Cs isotopes","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Exploring analytical potential of ICP-MS for the determination of radioactive Cs isotopes"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-01-08"},"publish_date":"2014-01-08","publish_status":"0","recid":"54437","relation_version_is_last":true,"title":["Exploring analytical potential of ICP-MS for the determination of radioactive Cs isotopes"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:00:57.760565+00:00"}