{"created":"2023-05-15T14:39:35.282743+00:00","id":54371,"links":{},"metadata":{"_buckets":{"deposit":"5a046f25-1b35-41bc-ac68-fd566e8ee9c3"},"_deposit":{"created_by":1,"id":"54371","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"54371"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00054371","sets":["2"]},"author_link":["555385","555398","555388","555390","555392","555402","555386","555384","555382","555403","555387","555383","555400","555399","555396","555391","555389","555397","555394","555395","555393","555401"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-07","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"4082","bibliographicPageStart":"4080","bibliographicVolumeNumber":"3rd","bibliographic_titles":[{"bibliographic_title":"IPAC : Contributions to the Proceedings"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"An isocentric superconducting rotating-gantry for heavy-ion therapy is being designed. This rotating gantry can transport heavy ions having 430 MeV/u to an\nisocenter with irradiation angles over 0-360 degrees, and is further capable of performing the fast raster-scanning irradiation. For the magnets, combined-function\nsuperconducting-magnets were employed. The use of these superconducting magnets allowed us to design a compact gantry, while keeping a large scan size at the\nisocenter. The superconducting magnets were designed by using a 3D electromagnetic-field solver, the OPERA-3D code. To verify the design of the magnets, beam tracking\nsimulations were performed. Consequently, we found that calculated beam profiles at the isocenter agreed well with those, designed by the beam optics, proving the validity of our design.","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Iwata, Yoshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"555382","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Noda, Kouji"}],"nameIdentifiers":[{"nameIdentifier":"555383","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shirai, Toshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"555384","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Furukawa, Takuji"}],"nameIdentifiers":[{"nameIdentifier":"555385","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fujita, Takashi"}],"nameIdentifiers":[{"nameIdentifier":"555386","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mori, Shinichiro"}],"nameIdentifiers":[{"nameIdentifier":"555387","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mizushima, Kota"}],"nameIdentifiers":[{"nameIdentifier":"555388","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Itano, Akifumi"}],"nameIdentifiers":[{"nameIdentifier":"555389","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fujimoto, Tetsuya"}],"nameIdentifiers":[{"nameIdentifier":"555390","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Amemiya, Naoyuki"}],"nameIdentifiers":[{"nameIdentifier":"555391","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ogitsu, Toru"}],"nameIdentifiers":[{"nameIdentifier":"555392","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"555393","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岩田 佳之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"555394","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"野田 耕司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"555395","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"白井 敏之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"555396","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古川 卓司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"555397","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤田 敬","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"555398","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"森 慎一郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"555399","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水島 康太","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"555400","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"板野 明史","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"555401","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"雨宮 尚之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"555402","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"荻津 透","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"555403","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"DESIGN OF SUPERCONDUCTING ROTATING-GANTRY FOR HEAVY-ION THERAPY","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"DESIGN OF SUPERCONDUCTING ROTATING-GANTRY FOR HEAVY-ION THERAPY"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-05-14"},"publish_date":"2013-05-14","publish_status":"0","recid":"54371","relation_version_is_last":true,"title":["DESIGN OF SUPERCONDUCTING ROTATING-GANTRY FOR HEAVY-ION THERAPY"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:01:43.861961+00:00"}