{"created":"2023-05-15T14:39:31.334424+00:00","id":54281,"links":{},"metadata":{"_buckets":{"deposit":"34263691-4975-41c7-aad6-fcf15c6eb219"},"_deposit":{"created_by":1,"id":"54281","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"54281"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00054281","sets":["2"]},"author_link":["554425","554432","554435","554431","554434","554428","554437","554438","554424","554436","554426","554427","554433","554429","554430","554423"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010-07","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"NIRS-M-232","bibliographicPageStart":"65","bibliographicVolumeNumber":"第5回","bibliographic_titles":[{"bibliographic_title":"技術と安全の報告会報告集"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"アブストラクト(日) PIXE分析法は、少ない試料でも繰り返し測定でき、定量可能な多元素同時分析法ということから、近年、多くの研究・教育機関でエアロゾル、水生生物などの環境試料の解析に利用されている。しかし、定量のためには、イオンビーム照射量を正確に知ることが重要であるが、真空中に試料をおくPIXE分析法では、試料によって厚みや状態が異なるので、ターゲットとなる試料の電流積算値が照射量に比例するとは限らない。そのため、PIXE分析において試料の状態に依らず、照射量を正確に制御できるリアルタイムビームモニタの開発を行ってきた。\n本報告会では、現在までに開発してきたコンベンショナルPIXEのリアルタイムビームモニタの現状について報告する。","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"石川, 剛弘"}],"nameIdentifiers":[{"nameIdentifier":"554423","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"及川, 将一"}],"nameIdentifiers":[{"nameIdentifier":"554424","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"磯, 浩之"}],"nameIdentifiers":[{"nameIdentifier":"554425","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酢屋, 徳啓"}],"nameIdentifiers":[{"nameIdentifier":"554426","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小西, 輝昭"}],"nameIdentifiers":[{"nameIdentifier":"554427","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"樋口, 有一"}],"nameIdentifiers":[{"nameIdentifier":"554428","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村, 尚"}],"nameIdentifiers":[{"nameIdentifier":"554429","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関, 等"}],"nameIdentifiers":[{"nameIdentifier":"554430","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川 剛弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"554431","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"及川 将一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"554432","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"磯 浩之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"554433","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酢屋 徳啓","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"554434","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小西 輝昭","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"554435","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"樋口 有一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"554436","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村 尚","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"554437","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関 等","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"554438","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"PIXE用リアルタイムビームモニタ開発の現状","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"PIXE用リアルタイムビームモニタ開発の現状"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-02-03"},"publish_date":"2011-02-03","publish_status":"0","recid":"54281","relation_version_is_last":true,"title":["PIXE用リアルタイムビームモニタ開発の現状"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:02:47.184181+00:00"}