@inproceedings{oai:repo.qst.go.jp:00053907, author = {岩田, 佳之 and 山田, 聰 and 村上, 健 and 藤本, 哲也 and 宮原, 信幸 and 小川, 博嗣 and 藤澤, 高志 and 北條, 悟 and 竹内, 猛 and 村松, 正幸 and その他 and 岩田 佳之 and 山田 聰 and 村上 健 and 宮原 信幸 and 小川 博嗣 and 藤澤 高志 and 北條 悟 and 村松 正幸}, book = {日本加速器学会年会・リニアック技術研究会}, month = {Nov}, note = {A compact injector, designed for a heavy-ion medical accelerator complex, was developed. It consists of an Electron-Cyclotron-Resonance Ion-Source (ECRIS) and two linacs, which are a Radio-Frequency-Quadrupole (RFQ) linac and an Alternating-Phase-Focused Interdigital H-mode Drift-Tube-Linac (APF IH-DTL) having the same operating frequency of 200 MHz. The compact injector can accelerate carbon ions of 12C4+ up to 4.0 MeV/u. The APF IH-DTL uses the APF method for beam focusing and the IH structure for the cavity. Use of the APF IH-DTL enabled us to design the compact injector; the total length of the two linacs is approximately 6 m. The compact injector was constructed, beam acceleration tests were performed. We have succeeded to accelerate carbon ions with satisfactory performance. An overview of the APF IH-DTL as well as results of the beam acceleration tests is described.}, pages = {127--129}, title = {APF方式IH型線形加速器の開発}, volume = {4}, year = {2007} }