{"created":"2023-05-15T14:39:14.466005+00:00","id":53903,"links":{},"metadata":{"_buckets":{"deposit":"52f1ff9e-545a-47b2-9bdb-d430aafaebae"},"_deposit":{"created_by":1,"id":"53903","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"53903"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00053903","sets":["2"]},"author_link":["550008","550013","550010","550009","550012","550011"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-06","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"60","bibliographicPageStart":"57","bibliographic_titles":[{"bibliographic_title":"Proceedings of the Symposium on Accelerator and Related Technology for Application"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A two-dimensionally position sensitive dosimetry system has tested for different dosimetric applications in a radiation therapy facility with a carbon beam. The system consist of a scintillating screen, mirror, mounted at the beam-exit side of a water phantom and it is observed by a low noise CCD camera with an integration time. Comparison between light distribution and ionization chamber measurement was carried out with carbon ion beam at HIMAC.","subitem_description_type":"Abstract"}]},"item_10003_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1344-4514","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"早乙女, 直也"}],"nameIdentifiers":[{"nameIdentifier":"550008","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金井, 達明"}],"nameIdentifiers":[{"nameIdentifier":"550009","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"加瀬, 優紀"}],"nameIdentifiers":[{"nameIdentifier":"550010","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"早乙女 直也","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"550011","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金井 達明","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"550012","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"加瀬 優紀","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"550013","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"眼治療用照射野確認システムの開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"眼治療用照射野確認システムの開発"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2007-11-07"},"publish_date":"2007-11-07","publish_status":"0","recid":"53903","relation_version_is_last":true,"title":["眼治療用照射野確認システムの開発"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:07:11.918291+00:00"}