@inproceedings{oai:repo.qst.go.jp:00053892, author = {加瀬, 優紀 and 松藤, 成弘 and 古川, 卓司 and 金井, 達明 and 加瀬 優紀 and 松藤 成弘 and 古川 卓司 and 金井 達明}, book = {Proceedings of the Symposium on Accelerator and Related Technology for Application}, month = {Dec}, note = {In a treatment planning of heave-ion radiotherapy, it is necessary to estimate the biological effect of the heave-ion beams. Physical dose should be associated with the relative biological effectiveness at each point. Presently, carbon ion radiotherapy has been carried out at the National Institute Radiological Sciences in Japan and the Gesellschaft fur Schwerionenforschung mbH in Germany. Both facilities take individual approach for the calculation of the RBE value. At NIRS, the classical system LQ Model has been used while the local effect model has been incorporated into the treatment planning system at GSI. The first aim of this study is to explain the RBE model of NIRS by the microdosimetric kinetic model. In addition, the clarification of similarities and differences between the MKM and LEM was also investigated.}, pages = {43--46}, title = {高エネルギー重粒子線におけるトラック構造を用いた生物物理モデルの検証}, year = {2007} }