{"created":"2023-05-15T14:39:12.069415+00:00","id":53849,"links":{},"metadata":{"_buckets":{"deposit":"4a7c2f06-038c-4687-a98d-7cd410606af0"},"_deposit":{"created_by":1,"id":"53849","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"53849"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00053849","sets":["2"]},"author_link":["549536","549533","549531","549540","549539","549535","549532","549537","549538","549529","549530","549534"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"NIRS-M-201","bibliographicPageEnd":"51","bibliographicPageStart":"49","bibliographicVolumeNumber":"第2回","bibliographic_titles":[{"bibliographic_title":"技術と安全の報告会報告集"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"PIXE分析法は、加速されたイオンビームを試料に照射し、放出される特性X線のエネルギーを測定して元素分析を行う方法である。この方法は、少ない試料でも繰り返し測定できる、定量可能な多元素同時分析法ということから、近年、加速器を持つ様々な研究・教育機関でエアロゾルなど、環境試料の解析を目的として開発、利用されるようになってきた。しかしながら、定量のためには、イオンビーム照射量を正確に知ることが重要であるが、真空中に試料をおくコンベンショナルなPIXE分析法では、試料によって厚みや状態が異なるので、ターゲットとなる試料の電流積算値が照射量に比例するとは限らない。放射線医学総合研究所ではPIXE分析において試料の状態に依らず、照射量を正確に制御できる装置の開発を行った。","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"石川, 剛弘"}],"nameIdentifiers":[{"nameIdentifier":"549529","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"磯, 浩之"}],"nameIdentifiers":[{"nameIdentifier":"549530","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小西, 輝昭"}],"nameIdentifiers":[{"nameIdentifier":"549531","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村, 尚"}],"nameIdentifiers":[{"nameIdentifier":"549532","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"濱野, 毅"}],"nameIdentifiers":[{"nameIdentifier":"549533","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関, 等"}],"nameIdentifiers":[{"nameIdentifier":"549534","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川 剛弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"549535","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"磯 浩之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"549536","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小西 輝昭","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"549537","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村 尚","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"549538","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"濱野 毅","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"549539","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今関 等","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"549540","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"PIXE分析法におけるビーム電流リアルタイム測定システムの開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"PIXE分析法におけるビーム電流リアルタイム測定システムの開発"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2007-05-15"},"publish_date":"2007-05-15","publish_status":"0","recid":"53849","relation_version_is_last":true,"title":["PIXE分析法におけるビーム電流リアルタイム測定システムの開発"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:07:49.937602+00:00"}